soft starter for asynchronous motor, Altistart 48, 156A, 208..690V, 37..160kW
ATS48C17Y
| Range of Product | Altistart 48 |
| Product or Component Type | Soft starter |
| product destination | Asynchronous motors |
| Product Specific Application | Heavy duty industry and pumps |
| Device short name | ATS48 |
| Utilisation category | AC-53A |
| Ue power supply voltage | 208…690 V – 15…10 % |
| power supply frequency | 50…60 Hz – 5…5 % |
| Motor power kW | 110 kW 500 V for standard applications |
| 110 kW 525 V for standard applications | |
| 110 kW 660 V for severe applications | |
| 110 kW 690 V for severe applications | |
| 132 kW 660 V for standard applications | |
| 160 kW 690 V for standard applications | |
| 37 kW 230 V for severe applications | |
| 45 kW 230 V for standard applications | |
| 75 kW 400 V for severe applications | |
| 75 kW 440 V for severe applications | |
| 90 kW 400 V for standard applications | |
| 90 kW 440 V for standard applications | |
| 90 kW 500 V for severe applications | |
| 90 kW 525 V for severe applications | |
| Maximum Horse Power Rating | 100 hp 460 V for severe applications |
| 125 hp 460 V for standard applications | |
| 125 hp 575 V for severe applications | |
| 150 hp 575 V for standard applications | |
| 40 hp 208 V for severe applications | |
| 50 hp 208 V for standard applications | |
| 50 hp 230 V for severe applications | |
| 60 hp 230 V for standard applications |
| Device connection | In the motor supply line |
| Protection type | Phase failure: line |
| Thermal protection: motor | |
| Thermal protection: starter | |
| Standards | EN/IEC 60947-4-2 |
| Product certifications | GOST |
| CCC | |
| C-Tick | |
| TCF | |
| SEPRO | |
| NOM 117 | |
| UL | |
| CSA | |
| DNV | |
| marking | CE |
| Discrete input number | 5 |
| Discrete input type | PTC, 750 Ohm at 25 掳C |
| (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | |
| Discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
| Minimum switching current | 10 mA at 6 V DC for relay outputs |
| Discrete output number | 2 |
| Discrete output type | (LO1) logic output 0 V common configurable |
| (LO2) logic output 0 V common configurable | |
| (R1) relay outputs fault relay NO | |
| (R2) relay outputs end of starting relay NO | |
| (R3) relay outputs motor powered NO | |
| Analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
| Communication port protocol | Modbus |
| Connector type | 1 RJ45 |
| Communication data link | Serial |
| Physical interface | RS485 multidrop |
| Transmission rate | 4800, 9600 or 19200 bps |
| Function available | External bypass (optional) |
| Operating position | Vertical +/- 10 degree |
| Height | 340 mm |
| Width | 200 mm |
| Depth | 265 mm |
| net weight | 12.4 kg |
| Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2 |
| Conducted and radiated emissions level B IEC 60947-4-2 | |
| Damped oscillating waves level 3 IEC 61000-4-12 | |
| Electrostatic discharge level 3 IEC 61000-4-2 | |
| Immunity to electrical transients level 4 IEC 61000-4-4 | |
| Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 | |
| Voltage/current impulse level 3 IEC 61000-4-5 | |
| Relative humidity | 0…95 % without condensation or dripping water EN/IEC 60068-2-3 |
| Ambient air temperature for operation | 104…140 °F (40…60 °C) with current derating of 2 % per °C) |
| 14…104 °F (-10…40 °C) without derating) | |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Operating altitude | <= 3280.84 ft (1000 m) without derating |
| > 3280.84…6561.68 ft (> 1000…2000 m) with current derating of 2.2 % per additional 100 m |
| Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2 |
| Conducted and radiated emissions level B IEC 60947-4-2 | |
| Damped oscillating waves level 3 IEC 61000-4-12 | |
| Electrostatic discharge level 3 IEC 61000-4-2 | |
| Immunity to electrical transients level 4 IEC 61000-4-4 | |
| Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 | |
| Voltage/current impulse level 3 IEC 61000-4-5 | |
| Relative humidity | 0…95 % without condensation or dripping water EN/IEC 60068-2-3 |
| Ambient air temperature for operation | 104…140 °F (40…60 °C) with current derating of 2 % per °C) |
| 14…104 °F (-10…40 °C) without derating) | |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Operating altitude | <= 3280.84 ft (1000 m) without derating |
| > 3280.84…6561.68 ft (> 1000…2000 m) with current derating of 2.2 % per additional 100 m |