| Main |
| Range of Product |
Altivar Machine ATV340 |
| Product or Component Type |
Variable speed drive |
| Product Specific Application |
Machine |
| variant |
Standard version |
| Mounting Mode |
Wall mount |
| Communication Port Protocol |
Modbus serial |
| EtherNet/IP |
| Modbus TCP |
| Option card |
communication module, PROFINET |
| communication module, DeviceNet |
| communication module, CANopen |
| communication module, EtherCAT |
| Phase |
3 phase |
| Supply frequency |
50…60 Hz +/- 5 % |
| [Us] rated supply voltage |
380…480 V – 15…10 % |
| Nominal output current |
145.0 A |
| Motor power kW |
90 kW normal duty |
| 75 kW heavy duty |
| Maximum Horse Power Rating |
125 hp normal duty |
| 100 hp heavy duty |
| EMC filter |
Class C3 EMC filter integrated |
| IP degree of protection |
IP20 |
| Degree of protection |
UL type 1 |
| Complementary |
| Discrete input number |
8 |
| Discrete input type |
PTI safe torque off 0…30 kHz, 24 V DC 30 V) |
| DI1…DI5 programmable as pulse input, 24 V DC 30 V)3.5 kOhm |
| programmable |
| number of preset speeds |
16 preset speeds |
| Discrete output number |
1 |
| Discrete output type |
Programmable output DQ1, DQ2 30 V DC 100 mA |
| Analogue input number |
3 |
| Analogue input type |
AI1 software-configurable current 0…20 mA 250 Ohm 12 bits |
| AI1 software-configurable temperature probe or water level sensor |
| AI1 software-configurable voltage 0…10 V DC 31.5 kOhm 12 bits |
| AI2 software-configurable voltage – 10…10 V DC 31.5 kOhm 12 bits |
| Analogue output number |
2 |
| Analogue output type |
Software-configurable voltage AQ1, AQ2 0…10 V DC 470 Ohm 10 bits |
| Software-configurable current AQ1, AQ2 0…20 mA 500 Ohm 10 bits |
| Relay output number |
3 |
| Output voltage |
<= power supply voltage |
| Relay output type |
Relay outputs R1A |
| Relay outputs R1C 100000 cycles |
| Relay outputs R2A |
| Relay outputs R2C 100000 cycles |
| Maximum switching current |
Relay output R1C resistive, cos phi = 1 3 A 250 V AC |
| Relay output R1C resistive, cos phi = 1 3 A 30 V DC |
| Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC |
| Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| Relay output R2C resistive, cos phi = 1 5 A 250 V AC |
| Relay output R2C resistive, cos phi = 1 5 A 30 V DC |
| Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC |
| Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| Minimum switching current |
Relay output R1B 5 mA 24 V DC |
| Relay output R2C 5 mA 24 V DC |
| Physical interface |
2-wire RS 485 |
| Connector Type |
3 RJ45 |
| Method of access |
Slave Modbus RTU |
| Slave Modbus TCP |
| Transmission Rate |
4.8 kbit/s |
| 9.6 kbit/s |
| 19.2 kbit/s |
| 38.4 kbit/s |
| Transmission frame |
RTU |
| Number of addresses |
1…247 |
| Data format |
8 bits, configurable odd, even or no parity |
| Type of polarization |
No impedance |
| 4 quadrant operation possible |
TRUE |
| Asynchronous motor control profile |
Variable torque standard |
| Constant torque standard |
| Optimized torque mode |
| Synchronous motor control profile |
Reluctance motor |
| Permanent magnet motor |
| Pollution degree |
2 IEC 61800-5-1 |
| Maximum output frequency |
0.599 kHz |
| Acceleration and deceleration ramps |
S, U or customized |
| Linear adjustable separately from 0.01…9999 s |
| Motor slip compensation |
Adjustable |
| Not available in permanent magnet motor law |
| Automatic whatever the load |
| Can be suppressed |
| Switching frequency |
1…8 kHz adjustable |
| 2.5…8 kHz with derating factor |
| Nominal switching frequency |
2.5 kHz |
| Braking to standstill |
By DC injection |
| Brake chopper integrated |
TRUE |
| Line current |
156.2 A 380 V normal duty) |
| 135.8 A 480 V normal duty) |
| 134.3 A 380 V heavy duty) |
| 118.1 A 480 V heavy duty) |
| Line current |
156.2 A 380 V with internal line choke normal duty) |
| 135.8 A 480 V with internal line choke normal duty) |
| 134.3 A 380 V with internal line choke heavy duty) |
| 118.1 A 480 V with internal line choke heavy duty) |
| 134.3 A |
| 118.1 A |
| Maximum Input Current per Phase |
156.2 A |
| Maximum output voltage |
480 V |
| Apparent power |
112.9 kVA 480 V normal duty) |
| 98.2 kVA 480 V heavy duty) |
| Maximum transient current |
207.6 A 60 s normal duty) |
| 217.5 A 60 s heavy duty) |
| 207.6 A 2 s normal duty) |
| 217.5 A 2 s heavy duty) |
| Electrical connection |
Screw terminal 0.75…1.5 mm² control |
| Screw terminal 120 mm² line side |
| Screw terminal 95…120 mm² DC bus |
| Screw terminal 120 mm² motor |
| Prospective line Isc |
50 kA |
| Base load current at high overload |
145.0 A |
| Base load current at low overload |
173.0 A |
| Power dissipation in W |
Natural convection 158 W 380 V 4 kHz heavy duty) |
| Forced convection 1359 W 380 V 4 kHz heavy duty) |
| Natural convection 180 W 380 V 4 kHz normal duty) |
| Forced convection 1585 W 380 V 4 kHz normal duty) |
| Electrical connection |
Control screw terminal 0.75…1.5 mm² AWG 18…AWG 16 |
| Line side screw terminal 120 mm² AWG 4/0…250 kcmil |
| DC bus screw terminal 95…120 mm² AWG 3/0…250 kcmil |
| Motor screw terminal 120 mm² 250 kcmil |
| With safety function Safely Limited Speed (SLS) |
TRUE |
| With safety function Safe brake management (SBC/SBT) |
TRUE |
| With safety function Safe Operating Stop (SOS) |
FALSE |
| With safety function Safe Position (SP) |
FALSE |
| With safety function Safe programmable logic |
FALSE |
| With safety function Safe Speed Monitor (SSM) |
FALSE |
| With safety function Safe Stop 1 (SS1) |
TRUE |
| With sft fct Safe Stop 2 (SS2) |
FALSE |
| With safety function Safe torque off (STO) |
TRUE |
| With safety function Safely Limited Position (SLP) |
FALSE |
| With safety function Safe Direction (SDI) |
FALSE |
| Protection type |
Thermal protection motor |
| Safe torque off motor |
| Motor phase loss motor |
| Thermal protection drive |
| Safe torque off drive |
| Overheating drive |
| Overcurrent drive |
| Output overcurrent between motor phase and earth drive |
| Output overcurrent between motor phases drive |
| Short-circuit between motor phase and earth drive |
| Short-circuit between motor phases drive |
| Motor phase loss drive |
| DC Bus overvoltage drive |
| Line supply overvoltage drive |
| Line supply undervoltage drive |
| Input supply loss drive |
| Exceeding limit speed drive |
| Break on the control circuit drive |
| Width |
10.7 in (271.0 mm) |
| Height |
35.7 in (908.0 mm) |
| Depth |
12.2 in (309.0 mm) |
| Net Weight |
128.8 lb(US) (58.4 kg) |
| Continuous output current |
173 A 4 kHz normal duty |
| 145 A 4 kHz heavy duty |
| Environment |
| Operating altitude |
<= 4800 m with current derating above 1000m |
| Operating position |
Vertical +/- 10 degree |
| Product Certifications |
UL |
| CSA |
| TÜV |
| EAC |
| CTick |
| Marking |
CE |
| Standards |
IEC 61800-3 |
| IEC 61800-5-1 |
| IEC 60721-3 |
| IEC 61508 |
| IEC 13849-1 |
| UL 618000-5-1 |
| UL 508C |
| IEC 61000-3-12 |
| Maximum THDI |
<48 % full load IEC 61000-3-12 |
| <48 % 80 % load IEC 61000-3-12 |
| Assembly style |
With heat sink |
| Electromagnetic compatibility |
Electrostatic discharge immunity test level 3 IEC 61000-4-2 |
| Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
| Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 |
| 1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5 |
| Conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
| Environmental class (during operation) |
Class 3C3 according to IEC 60721-3-3 |
| Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) |
150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) |
10 m/s² at 13…200 Hz |
| Maximum deflection under vibratory load (during operation) |
1.5 mm at 2…13 Hz |
| Permitted relative humidity (during operation) |
Class 3K5 according to EN 60721-3 |
| Volume of cooling air |
77932.2 Gal/hr(US) (295.0 m3/h) |
| Type of cooling |
Forced convection |
| Overvoltage category |
Class III |
| Regulation loop |
Adjustable PID regulator |
| Noise level |
69.9 dB |
| Pollution degree |
2 |
| Ambient air transport temperature |
-40…158 °F (-40…70 °C) |
| Ambient air temperature for operation |
5…104 °F (-15…40 °C) without derating vertical position) |
| 104…122 °F (40…50 °C) with derating factor vertical position) |
| Ambient Air Temperature for Storage |
-40…158 °F (-40…70 °C) |
| Isolation |
Between power and control terminals |
| Ordering and shipping details |
| Category |
US1CP4B22183 |
| Discount Schedule |
CP4B |
| GTIN |
3606480967139 |
| Returnability |
No |
| Country of origin |
CN |