| Main |
| Range of Product |
Altivar 12 |
| Product or Component Type |
Variable speed drive |
| Product Specific Application |
Simple machine |
| Mounting Mode |
Cabinet mount |
| Communication Port Protocol |
Modbus |
| Supply frequency |
50/60 Hz +/- 5 % |
| [Us] rated supply voltage |
200…240 V – 15…10 % |
| Nominal output current |
10 A |
| Maximum Horse Power Rating |
3 hp |
| Motor power kW |
2.2 kW |
| Maximum Horse Power Rating |
3 hp |
| EMC filter |
Without EMC filter |
| IP degree of protection |
IP20 |
| Complementary |
| Discrete input number |
4 |
| Discrete output number |
2 |
| Analogue input number |
1 |
| Analogue output number |
1 |
| Relay output number |
1 |
| Physical interface |
2-wire RS 485 |
| Connector Type |
1 RJ45 |
| Continuous output current |
10 A 4 kHz |
| Method of access |
Server Modbus serial |
| Speed drive output frequency |
0.5…400 Hz |
| Speed range |
1…20 |
| Sampling duration |
20 ms +/- 1 ms logic input |
| 10 ms analogue input |
| Linearity error |
+/- 0.3 % of maximum value analogue input |
| Frequency resolution |
Analog input converter A/D, 10 bits |
| Display unit 0.1 Hz |
| Time constant |
20 ms +/- 1 ms for reference change |
| Transmission Rate |
9.6 kbit/s |
| 19.2 kbit/s |
| 38.4 kbit/s |
| Transmission frame |
RTU |
| Number of addresses |
1…247 |
| Data format |
8 bits, configurable odd, even or no parity |
| Communication service |
Read holding registers (03) 29 words |
| Write single register (06) 29 words |
| Write multiple registers (16) 27 words |
| Read/write multiple registers (23) 4/4 words |
| Read device identification (43) |
| Type of polarization |
No impedance |
| 4 quadrant operation possible |
FALSE |
| Asynchronous motor control profile |
Quadratic voltage/frequency ratio |
| Sensorless flux vector control |
| Voltage/frequency ratio (V/f) |
| Maximum output frequency |
4 kHz |
| Transient overtorque |
150…170 % of nominal motor torque depending on drive rating and type of motor |
| Acceleration and deceleration ramps |
Linear from 0 to 999.9 s |
| S |
| U |
| Motor slip compensation |
Adjustable |
| Preset in factory |
| Switching frequency |
2…16 kHz adjustable |
| 4…16 kHz with derating factor |
| Nominal switching frequency |
4 kHz |
| Braking to standstill |
By DC injection |
| Brake chopper integrated |
FALSE |
| Line current |
14.9 A 100 V heavy duty) |
| 12.5 A 120 V heavy duty) |
| Maximum Input Current per Phase |
12.5 A |
| Maximum output voltage |
240 V |
| Apparent power |
5.2 kVA 240 V heavy duty) |
| Maximum transient current |
15.0 A 60 s heavy duty) |
| 16.5 A 2 s heavy duty) |
| Network Frequency |
50-60 Hz |
| Relative symmetric network frequency tolerance |
5% |
| Prospective line Isc |
5 kA |
| Base load current at high overload |
10.0 A |
| Power dissipation in W |
Forced cooling 85.0 W |
| With safety function Safely Limited Speed (SLS) |
FALSE |
| With safety function Safe brake management (SBC/SBT) |
FALSE |
| With safety function Safe Operating Stop (SOS) |
FALSE |
| With safety function Safe Position (SP) |
FALSE |
| With safety function Safe programmable logic |
FALSE |
| With safety function Safe Speed Monitor (SSM) |
FALSE |
| With safety function Safe Stop 1 (SS1) |
FALSE |
| With sft fct Safe Stop 2 (SS2) |
FALSE |
| With safety function Safe torque off (STO) |
FALSE |
| With safety function Safely Limited Position (SLP) |
FALSE |
| With safety function Safe Direction (SDI) |
FALSE |
| Protection type |
Line supply overvoltage |
| Line supply undervoltage |
| Overcurrent between output phases and earth |
| Overheating protection |
| Short-circuit between motor phases |
| Against input phase loss in three-phase |
| Thermal motor protection via the drive by continuous calculation of I²t |
| Tightening torque |
10.6 lbf.in (1.2 N.m) |
| Insulation |
Electrical between power and control |
| Quantity per Set |
Set of 1 |
| Width |
4.1 in (105 mm) |
| Height |
5.6 in (143 mm) |
| Depth |
5.2 in (131.2 mm) |
| Product Weight |
2.6 lb(US) (1.2 kg) |
| Environment |
| Operating altitude |
<= 3280.84 ft (1000 m) without derating |
| > 3280.84…9842.52 ft (> 1000…3000 m) with current derating 1 % per 100 m |
| Operating position |
Vertical +/- 10 degree |
| Product Certifications |
NOM |
| CSA |
| C-tick |
| UL |
| GOST |
| RCM |
| KC |
| marking |
CE |
| Standards |
UL 508C |
| UL 618000-5-1 |
| IEC 61800-5-1 |
| IEC 61800-3 |
| Assembly style |
With heat sink |
| Electromagnetic compatibility |
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 |
| Electrostatic discharge immunity test level 3 IEC 61000-4-2 |
| Immunity to conducted disturbances level 3 IEC 61000-4-6 |
| Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
| Surge immunity test level 3 IEC 61000-4-5 |
| Voltage dips and interruptions immunity test IEC 61000-4-11 |
| Environmental class (during operation) |
Class 3C3 according to IEC 60721-3-3 |
| Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) |
150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) |
10 m/s² at 13…200 Hz |
| Maximum deflection under vibratory load (during operation) |
1.5 mm at 2…13 Hz |
| Volume of cooling air |
3909.8 Gal/hr(US) (14.8 m3/h) |
| Overvoltage category |
Class III |
| Regulation loop |
Adjustable PID regulator |
| Electromagnetic emission |
Radiated emissions environment 1 category C2 IEC 61800-3 2…16 kHz shielded motor cable |
| Conducted emissions with additional EMC filter environment 1 category C1 IEC 61800-3 4…12 kHz shielded motor cable <16.4 ft (5 m) |
| Conducted emissions with additional EMC filter environment 1 category C2 IEC 61800-3 4…12 kHz shielded motor cable <65.6 ft (20 m) |
| Conducted emissions with additional EMC filter environment 2 category C3 IEC 61800-3 4…12 kHz shielded motor cable <65.6 ft (20 m) |
| Vibration resistance |
1 gn 13…200 Hz)IEC 60068-2-6 |
| 1.5 mm peak to peak 3…13 Hz) – drive unmounted on symmetrical DIN rail – IEC 60068-2-6 |
| Shock resistance |
15 gn 11 ms IEC 60068-2-27 |
| Relative humidity |
5…95 % without condensation IEC 60068-2-3 |
| 5…95 % without dripping water IEC 60068-2-3 |
| Noise level |
50 dB |
| Pollution degree |
2 |
| Ambient air transport temperature |
-13.0000000000…158.0000000000 °F (-25…70 °C) |
| Ambient air temperature for operation |
14.0000000000…122.0000000000 °F (-10…50 °C) without derating |
| 122.0000000000…140.0000000000 °F (50…60 °C) with current derating 2.2 % per °C |
| Ambient Air Temperature for Storage |
-13.0000000000…158.0000000000 °F (-25…70 °C) |
| Ordering and shipping details |
| Category |
US1CP4B22042 |
| Discount Schedule |
CP4B |
| GTIN |
3606480071188 |
| Returnability |
Yes |
| Country of origin |
US |