ABB PSTB470-600-70 Softstarter 470A Main Circuit 208 … 600V AC

Alternate PN: PSTB47060070
Manufacturer Brands: ABB
Place of Originr: Made in USA
Net Weight: 31 kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

PSTB470-600-70 Softstarter – 470 A – Main Circuit 208 … 600 V AC

Part Number
Manufacturer ABB
Model# PSTB470-600-70
Product Description PSTB470-600-70 Softstarter – 470 A
Main Circuit 208 … 600 V AC
Long Description: Softstarter PSTB470-600-70 for max 600V
main voltage and 110 – 240V 50/60Hz control supply voltage
Dimensions
Product Net Width: 366 mm
Product Net Height: 460 mm
Product Net Depth / Length: 361 mm
Product Net Weight: 31 kg
Technical
Rated Operational Voltage: Main Circuit 208 … 600 VAC
Rated Control Supply Voltage (Us): 100 … 250 VAC
Rated Control Circuit Voltage (Uc): DC Operation 24 V
Rated Frequency (f): 50/60 Hz
Main Circuit 50/60 Hz
Rated Operational Power – In-Line Connection (Pe): (400 V)250 kw
(500 V)315 kW
Rated Operational Current – In-Line Connection (Ie): 470 A
Rated Operational Power – Inside Delta Connection: at 400 V 450 kW
at 500 V 600 kW
Rated Operational Current – Inside Delta Connection: 814 A
Service Factor Percentage: 115%
Overload Protection: Build-in electronic overload protection
Integrated Electronic Overload: Yes
Adjustable Rated Motor Current Ie: 30 … 115 %
Starting Capacity at Maximum Rated Current Ie: 3xIe for 15s
Ramp Time: 0 … 120 second [unit of time]
1 … 120 second [unit of time]
Initial Voltage During Start: 30 … 70 %
Step Down Voltage Special Ramp: 100 … 30 %
Current Limit Function: 1.5 … 7xIe
Switch for Inside Delta Connection: Yes
Run Signal Relay: Yes
By-pass Signal Relay: Yes
Fault Signal Relay: Yes
Overload Signal Relay: Yes
Analog Outputs: 0…10 volts
0…20 mA
4…20 mA
Signal Indication Ready to Start/Standby ON (LED): Green
Signal Indication Protection (LED): Yellow
Signal Indication Fault (LED): Red
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time: 10
Communication: FiledBusPlug(Standard)
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type: Main Circuit: Bars
Connecting Capacity Main Circuit: Hole Diameter 10.5 mm
Width and Thickness 25×6 mm
Connecting Capacity Control Circuit: Rigid 1 x 2.5 mm²
Rigid 2 x 1.5 mm²
Connecting Capacity Supply Circuit: Rigid 1 x 2.5 mm²
Tightening Torque: Control Circuit 0.5 N·m
Main Circuit 35 N·m
Supply Circuit 0.5 N·m
Product Main Type: PSTB470