This datasheet defines the Siemens SINAMICS S120 Active Interface Module (AIM) 6SL3300-7TE41-4AA1, the successor to 6SL3300-7TE41-4AA0, designed for 630–900 kW Active Line Modules (ALM) 6SL3330‑7TE41‑0AA3/41‑4AA3 in chassis‑format industrial drive systems.
Core Product & Ordering Info
| Item | Detail |
|---|---|
| Part Number | 6SL3300-7TE41-4AA1 |
| Product Type | SINAMICS S120 Active Interface Module (AIM), chassis format |
| Replaces | 6SL3300-7TE41-4AA0 |
| Compatible ALM | 6SL3330‑7TE41‑0AA3 (630 kW), 6SL3330‑7TE41‑4AA3 (900 kW) |
| Core Functions | Clean Power Filter (basic RI suppression), pre‑charging circuit, line voltage sensing, monitoring sensors |
| Product Lifecycle | PM300: Active Product |
| Country of Origin | Germany |
Electrical Specifications
| Parameter | Value |
|---|---|
| Line Voltage | 380–480 V, 3‑phase |
| Frequency | 50/60 Hz (47–63 Hz tolerance) |
| Rated Current (900 kW ALM) | 1405 A (continuous) |
| Rated Current (630 kW ALM) | 985 A (continuous) |
| DC Link Voltage | 510–720 V DC (matches ALM output) |
| Rated Power | 630–900 kW (matches ALM rating) |
| EMC Compliance | Clean Power Filter (basic RI suppression); meets EN 61800‑3 |
| Control Voltage | 24 V DC (auxiliary power for control circuits) |
Mechanical & Environmental
| Parameter | Value |
|---|---|
| Frame Size | JI (chassis format) |
| Mounting | Built‑in unit (cannot operate standalone) |
| IP Rating | IP00 |
| Cooling | Internal air cooling |
| Operating Temperature | 0–40 °C (no derating up to 40 °C) |
| Storage Temperature | -25–70 °C |
| Relative Humidity | ≤80% (non‑condensing, 0–40 °C) |
| Altitude | ≤1000 m (derate 1% per 100 m above 1000 m, max 4000 m) |
| Net Weight | 551 kg |
| Vibration/Shock | Compliant with IEC 60068‑2‑6/2‑27 |
Interfaces & Key Components
| Interface/Component | Configuration |
|---|---|
| DRIVE‑CLiQ | Integrated port for ALM and Control Unit (CU) connection; includes DRIVE‑CLiQ cable with Pt1000 |
| Line Connection | 3× M12 sockets (line/load terminals) |
| Monitoring | Voltage/current sensing, temperature monitoring (Pt1000), pre‑charge status |
| Protections | Overcurrent, overvoltage, undervoltage, overtemperature, short‑circuit, EMC filtering |
| Bypass Contactor | Must be provided separately (JI frame) |
Key Features
- Clean Power Filter: Reduces line harmonics and RF interference for stable grid integration.
- Pre‑Charging Circuit: Safely charges DC link capacitors during startup, preventing inrush current damage.
- Seamless Integration: Works with SINAMICS S120 CU320‑2/CU310‑2 for centralized control and diagnostics.
- Enhanced Reliability: Improved component quality and factory testing vs. predecessor 6SL3300‑7TE41‑4AA0.
- Safety Compliance: Meets EN 61800‑5‑1 (functional safety) and IEC 61800‑3 (EMC).