Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA8075-6DV62-0AA0 SINAMICS DCM DC converter Input: 400V 3AC, 174A

Part Number: 6RA8075-6DV62-0AA0
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 15,00 Kg
Product Size: 520,00 x 380,00 x 390,00 mm

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
Order No.:6RA8075-6DV62-0AA0

Brand:Siemens

Series:SINAMICS DCM

Type:DC Converter, 4‑quadrant operation (motoring/regeneration, forward/reverse)

Topology:(B6)A (B6)C fully controlled 3‑phase bridge

Status:Active (in production)


1. Armature Input Specifications

Parameter Value
Input type 3‑phase AC
Rated input voltage 400 V AC, +15 % / −20 %
Permissible input voltage 380 … 480 V AC
Rated input current 174 A
Input frequency 45 … 65 Hz
Control electronics supply 2‑phase 380 … 480 V AC, 50/60 Hz
Fan supply Integrated, powered from main input

2. Armature Output Specifications

Parameter Value
Rated output voltage 420 V DC
Rated output current 210 A
Rated output power 88.2 kW
Operation mode 4‑quadrant
Dynamic overload 110% × 60 s; 150% × 5 s
Steady‑state overload 105% continuous (thermal‑limited)
Rectifier type Thyristor‑based, fully controlled

3. Built‑in Field Circuit Specifications

Parameter Value
Field rectifier model D420/210 MREQ‑GEGF6V62
Field input supply 2‑phase AC 380 … 480 V
Max. field output voltage Adjustable up to 420 V DC
Max. field output current 21 A
Field control Fully controllable, closed‑loop adjustable excitation
Function For separately excited DC motor field winding

4. Power, Loss & Efficiency

Parameter Value
Rated output power 88.2 kW
Typical power loss at rated load ~880 W
Typical efficiency ≥99.0 % at rated load

5. Mechanical & Environmental Data

Parameter Value
Dimensions (W×D×H) Approx. 390 × 520 × 600 mm
Net weight Approx. 65 kg
Protection class IP20
Cooling Forced ventilation (AF)
Ambient operating temperature 0 … 40 °C (derate above 40 °C)
Storage/transport temperature −40 … +70 °C
Installation altitude Up to 1000 m above sea level
Installation orientation Vertical, wall‑mounted

6. Standards & Certifications

Compliant with EN 50178, EN 60146‑1‑1, EN 61800‑1, EN 61800‑3, EN 61800‑5‑1, IEC 62103, UL/CSA recognized

7. Key Features & Applications

  • 4‑quadrant operation with regenerative braking capability
  • Integrated field power unit (no external field controller required)
  • 32‑bit microprocessor, high‑precision closed‑loop speed & current control
  • Support for encoder/tachometer feedback, high control accuracy
  • Comprehensive protection: overcurrent, overvoltage, undervoltage, overtemperature, phase loss, short circuit, field failure, overspeed
  • Suitable for rolling mills, extruders, cranes, elevators, test stands, wire drawing machines, presses, and high‑power industrial DC motor drives

Leave a Replay