6RA8078-6DV62-0AA0-Z G00 SIMATIC Rack PC 847B 110/230 V

Part Number: 6RA8078-6DV62-0AA0-Z G00
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 17,25 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
Order No.:6RA8078-6DV62-0AA0-Z G00

Brand:Siemens

Series:SINAMICS DCM

Type:DC Converter, 4‑quadrant operation (forward/reverse motoring & regenerative braking)

Topology:(B6)A + (B6)C fully controlled 3‑phase bridge

Option Z G00:Basic version, standard factory configuration, no special hardware/software variants

Status:Active (in production)


1. Armature Input Specifications

Parameter Value
Input type 3‑phase AC
Rated input voltage 400 V AC, +15% / −20%
Permissible input voltage 380 … 480 V AC
Rated input current 232 A
Input frequency 45 … 65 Hz
Control electronics supply 2‑phase AC 380 … 480 V, 50/60 Hz
Fan power supply Integrated, powered from main input

2. Armature Output Specifications

Parameter Value
Rated output voltage 420 V DC
Rated output current 280 A
Rated output power 117.6 kW
Operation mode 4‑quadrant
Dynamic overload 110% × 60 s; 150% × 5 s
Steady‑state overload 105% continuous (thermal‑limited)
Rectifier type Thyristor‑based, fully controlled

3. Built‑in Field Circuit Specifications

Parameter Value
Field rectifier model D420/280 MREQ‑GEGF6V62
Field input supply 2‑phase AC 380 … 480 V
Max. field output voltage Adjustable up to 420 V DC
Max. field output current 28 A
Field control Fully controllable, closed‑loop adjustable excitation
Function For separately excited DC motor field winding

4. Power, Loss & Efficiency

Parameter Value
Rated output power 117.6 kW
Typical power loss at rated load ~1180 W
Typical efficiency ≥99.0 % at rated load

5. Mechanical & Environmental Data

Parameter Value
Dimensions (W×D×H) Approx. 420 × 640 × 640 mm
Net weight Approx. 68 kg
Protection class IP20
Cooling Forced ventilation (AF)
Ambient operating temperature 0 … 40 °C (derate above 40 °C)
Storage/transport temperature −40 … +70 °C
Installation altitude Up to 1000 m above sea level
Installation orientation Vertical, wall‑mounted

6. Standards & Certifications

Compliant with EN 50178, EN 60146‑1‑1, EN 61800‑1, EN 61800‑3, EN 61800‑5‑1, IEC 62103, UL/CSA recognized

7. Protection Functions

  • Overcurrent, overvoltage, undervoltage protection
  • Overtemperature, phase failure, short‑circuit protection
  • Field loss, overspeed, motor overtemperature protection
  • Electronic thermal motor protection

8. Key Features & Applications

  • Full 4‑quadrant operation with regenerative energy feedback
  • Integrated field power unit (no external field controller required)
  • 32‑bit microprocessor, high‑precision closed‑loop speed & current control
  • Support for encoder/tachometer feedback, high dynamic performance
  • Wide speed regulation range, strong low‑speed torque output
  • Suitable for rolling mills, extruders, cranes, mine hoists, test stands, wire drawing machines, presses, and high‑power industrial DC motor drive systems