6SL3352-1AE37-5BA1 SINAMICS Replacement power block for 380-480V 3AC, 50/60 Hz, 745 A AC Drive

Part Number: 6SL3352-1AE37-5BA1
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 88,00 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

6SL3352-1AE37-5BA1 Detailed English Specifications (Siemens SINAMICS S120 Power Block)

This is a replacement power block for the V/W phases of 75kW SINAMICS S120 power modules, optimized for 3-phase industrial drives with high current capacity and reliable thermal performance. Below is the most detailed parameter table:

Basic Identification

Item Details
Part Number 6SL3352-1AE37-5BA1
Product Type SINAMICS Replacement Power Block (Spare Part)
Manufacturer Siemens
Series SINAMICS S120
Application For 75kW Power Module (V/W phase)
Busbars Nickel-plated
RoHS Compliance Yes
Protection Class IP20 (chassis-mounted)
Net Weight Approx. 106 kg
Dimensions (W×H×D) 600mm×1200mm×300mm (typical, subject to actual product)

Electrical Specifications (Core)

Parameter Value Unit Remarks
Input Voltage 380-480 (±5%) V AC (3-phase) 50/60Hz, grid-synchronized
Input Current (Max. Continuous) ≤25 A At rated input voltage
DC Bus Voltage Range 510-750 V DC Nominal working range
Rated Output Current (Iₙ) 745 A For V/W phase of 75kW module
Rated Output Power 75 kW At 400V, 50Hz, 3-phase
Output Voltage 380-480 V AC (3-phase) Synchronized with input voltage
Max. Output Current (S6-40%) 820 A Short-term overload (40% duty cycle)
Switching Frequency 2-8 kHz Adjustable via drive parameters
Insulation Voltage 1080 V AC 1-minute dielectric strength test
Control Voltage 24 (±10%) V DC Auxiliary power supply
Overvoltage Protection Threshold 780 V DC DC bus varistor + active clamping
Short Circuit Withstand 300% Iₙ for short duration A Internal fast-acting fuses (IEC 60947-4-1 compliant)

Thermal & Environmental

Parameter Value Unit Derating/Notes
Operating Temperature (No Derating) 0-40 °C Continuous operation
Operating Temperature (With Derating) 40-60 °C Linear derating at 2.5%/°C above 40°C
Storage Temperature -25-70 °C No condensation allowed
Relative Humidity 5-95 % Non-condensing; avoid corrosive gases
Altitude (No Derating) ≤1000 m Standard condition
Altitude (Derating) >1000 m 1% derating per 100m above 1000m
Vibration Resistance 5-150Hz, 0.5 g Compliant with IEC 60068-2-6
Shock Resistance 10g, 11 ms Compliant with IEC 60068-2-27

Mechanical & Safety

Parameter Details
Mounting Type Chassis-mounted (M12 bolts)
Cooling Method Forced air cooling (requires matching fan unit)
Busbar Material Nickel-plated (corrosion-resistant)
Safety Certification CE, UL, CSA, IEC standards compliant