This is a control module from Siemens’ SIMOREG DC Master series, designed for 4‑quadrant regenerative DC drive control, with no integrated power unit, rated field current 40 A (480 V DC), 400 V AC 3‑phase input, and optional features including D76 (field rectifier: 480 V DC/76 A), Profibus DP (G94), PMU operator panel (K01), RS485 serial interface (K11), and basic software (S00). It is widely used in industrial DC motor speed control systems requiring flexible configuration and communication integration. Below are the detailed parameter tables:
Basic Identification
| Item | Details |
|---|---|
| Part Number | 6RA7000-0MV62-0-Z D76+G94+K01+K11+S00 |
| Product Type | SIMOREG DC Master Control Module (no power unit, 4‑quadrant control) |
| Manufacturer | Siemens |
| Control Method | Microprocessor‑based digital control (vector control for DC motors) |
| Mounting Type | Rack‑mounted (IP20 chassis) |
| Protection Class | IP20 (chassis); IP30 (front panel) |
| Frame Size | Compact (C) |
| Net Weight | Approx. 18 kg (39.7 lbs) |
| Dimensions (W×H×D) | 300 mm × 400 mm × 250 mm (typical, subject to actual product) |
| Software Version | SIMOREG DC Master V5.1 (S00 basic software) |
| Order Option Codes | D76 (field rectifier: 480 V DC/76 A), G94 (Profibus DP interface), K01 (PMU operator panel), K11 (RS485 serial interface), S00 (basic software) |
| Discontinuation Status | Discontinued (replaced by 6RA8000‑0MV62‑0AA0) |
| Compliance | CE, UL, CSA, ATEX (Zone 2) |
Electrical Specifications (Control & Auxiliary)
| Parameter | Value | Unit | Remarks |
|---|---|---|---|
| Control Voltage | 24 (±15%) | V DC | Auxiliary power supply, current consumption 0.8 A |
| Input Voltage (3‑phase, Control Circuit) | 400 (±10%) | V AC | 50/60 Hz, grid‑synchronized |
| Insulation Voltage | 1400 | V AC (1 min) | Dielectric strength test value |
| Auxiliary Power Consumption | Approx. 19.2 | W | 24 V DC × 0.8 A |
Electrical Specifications (Field Circuit – D76 Option)
| Parameter | Value | Unit | Remarks |
|---|---|---|---|
| Field Rectifier Model | D76 | — | 480 V DC/76 A field output |
| Rated Field Output Voltage | 480 | V DC | Controllable 0‑480 V DC |
| Rated Field Output Current | 76 | A | Continuous operation |
| Field Overload Capacity | 114 | A | 150% of rated field current, 1 minute |
| Field Control Mode | Current‑controlled (CC) / Voltage‑controlled (VC) (switchable) | ||
| Field Insulation Voltage | 1000 | V AC (1 min) | Dielectric strength test value |
Hardware Configuration (Options Included)
| Component | Details |
|---|---|
| Communication Interface | G94 (Profibus DP, baud rate up to 12 Mbps); K11 (RS485 serial interface, Modbus RTU) |
| Operator Panel | K01 (PMU: Parameterization and Monitoring Unit) |
| Field Rectifier | D76 (thyristor bridge, 480 V DC/76 A) |
| Expansion Slots | 2 × optional I/O modules (for analog/digital I/O extension) |
| Protective Devices | Varistors for surge protection; electronic overload protection for field circuit |
Thermal & Environmental
| Parameter | Value | Unit | Derating/Notes |
|---|---|---|---|
| Operating Temperature (No Derating) | 0‑40 | °C | Continuous operation |
| Operating Temperature (Derating) | 40‑55 | °C | Linear derating at 2%/°C above 40°C |
| Storage Temperature | ‑25‑70 | °C | No condensation allowed |
| Relative Humidity | 5‑95 | % | Non‑condensing, no corrosive gases |
| Altitude (No Derating) | ≤1000 | m | Standard condition |
| Altitude (Derating) | >1000 | m | 1% derating per 100 m above 1000 m |
| Vibration Resistance | 5‑150 Hz, 0.5 | g | Compliant with IEC 60068‑2‑6 |
| Shock Resistance | 10 g, 11 | ms | Compliant with IEC 60068‑2‑27 |
| Sound Pressure Level (1 m) | ≤65 | dB (50/60 Hz) | Typical operation noise |
Safety & Protection Features
| Feature | Details |
|---|---|
| Overvoltage Protection | Varistors for control circuit surge protection |
| Overcurrent Protection | Electronic current limiting for field circuit (up to 114 A peak) |
| Overheating Protection | Thermal sensor (triggers at 85°C heatsink temperature) |
| Undervoltage Protection | Triggers at 320 V AC input (3‑phase) |
| Field Loss Protection | Detects field current loss and triggers shutdown |
| Motor Protection | Motor overload and stall protection (via software settings) |