- Catalog No.:6RA7093-4GV62-0-Z G97+K02+K11+S00
- Product Family:SIMOREG DC Master 6RA70 (Four‑Quadrant DC Drive Rectifier)
- Description:Microprocessor‑controlled 4‑quadrant DC drive converter; 3AC 575V input, 600V DC / 1600A armature output; field rectifier D600/1600 (375V DC / 40A); Discontinued (spare parts only); options: G97 (expansion board slot), K02 (ADB adapter board slot F/G), K11 (LBA backplane adapter), S00 (standard software/configuration)
- Net Weight:~145 kg (319.7 lbs)
- Dimensions:Typical 6RA70 heavy‑duty frame (W×D×H: ~400 × 600 × 800 mm; confirm with full manual)
- ECCN:EAR99
- Country of Origin:Germany
- Lifecycle:Discontinued (PM300), spare parts only; migrate to SINAMICS DCM for new projects
Key Technical Specifications
| Parameter | Value |
|---|---|
| Input Voltage | 3AC 575 V, 50/60 Hz |
| Input Current (Continuous) | 1326 A |
| Armature Output Voltage | 600 V DC (nominal) |
| Armature Output Current (Continuous) | 1600 A (global); 1190 A (US rating) |
| Armature Output Current (Peak) | ~2400 A (150% overload, short‑term) |
| Field Rectifier | D600/1600; 460 V AC input → 375 V DC / 40 A output |
| Control Type | Digital closed‑loop (speed/torque/current) |
| Topology | 4‑quadrant (B6A/B6C) thyristor bridge |
| Cooling | Separate forced air cooling (external fan required) |
| Enclosure | Open frame (IP20, panel‑mount) |
| Ambient Operating Temp | 0…+40°C (derate to +35°C at >1000m) |
| Storage Temp | -20…+60°C |
| Max Altitude | 1000 m (no derate); 2000 m (80% derate) |
| Relative Humidity | 5…95% (non‑condensing) |
| Compliance | CE, UL, cUL, EN 61800‑3 (EMC), EN 61131‑2 |
| Programming/Commissioning | DriveMonitor, STARTER (S7‑TIA Portal compatible) |
| Communication | PROFIBUS DP (optional CBP2 board), SIMOLINK (optional SLB board) |
| Protection | Overcurrent, overvoltage, overtemperature, earth fault, field failure |
Option Code Definitions (G97+K02+K11+S00)
| Code | Description |
|---|---|
| G97 | Expansion board slot assignment (EB1/EB2 mounting position) |
| K02 | ADB (Adapter Board) mounting position: Slot F + Slot G (6SX7010‑0KA0 compatible) |
| K11 | LBA (Backplane Adapter) installed in electronics box (for backplane bus extension) |
| S00 | Standard factory software/configuration (no special firmware/function package) |