Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6SL3210-1PE27-5UL0 SINAMICS G120 POWER MODULE 3AC 380-480V +10/-20% 47-63HZ

Part Number: 6SL3210-1PE27-5UL0
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 18,3 Kg
Product Size: 495,00 x 356,00 x 300,00 mm

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
This is the detailed English technical specification sheet for Siemens 6SN1145-1BA02-0CA2 SIMODRIVE 611 infeed/regenerative feedback module, covering core electrical ratings, performance, protection, mechanical/environmental data, and functional details, based on Siemens official documentation and certified industrial catalogs.

1. Core Electrical Specifications

Parameter Value Unit Notes
Product Model 6SN1145-1BA02-0CA2 SIMODRIVE 611 infeed/regenerative feedback module, closed-loop control, internal cooling, mains contactor with break contact
AC Input (3‑phase) 380–480 (rated: 400) V AC 3‑phase, 50/60 Hz, ±10% tolerance
AC Input Frequency 50–60 (±2%) Hz Grid frequency range
DC Link Voltage (Nominal) 650 V DC Closed-loop regulated DC bus voltage
Rated Infeed Power (Continuous) 36 kW Steady-state power for DC bus supply
Peak Infeed Power (Regenerative) 47 kW Short-term regenerative feedback power
Rated DC Link Current 90 A Continuous DC current for drive modules
Peak DC Link Current 180 (200% of rated) A For 3 s, with 10‑minute cool‑down interval
Power Factor (λ) 0.95 At rated infeed power
Efficiency (η) 0.97 At rated infeed power
Power Loss 1.08 kW Typical power loss under rated load

2. Overload Capabilities

Overload Condition Power Duration Ambient Temperature
Regenerative Peak 47 kW (130% of continuous) 3 s 0–45°C
Infeed Peak 47 kW (130% of continuous) 3 s 0–45°C
Continuous Operation 36 kW (100% rated) Continuous 0–45°C

3. Performance & Protection Specifications

Parameter Value Unit Notes
Control Type Closed-loop regulated Stabilized DC link voltage for precise motor control
Overcurrent Protection 200% of rated DC current Instantaneous trip to prevent device damage
Overvoltage Protection 720 V DC Active clamping via bus capacitor/discharge circuit
Undervoltage Protection 570 V DC Shuts down to prevent IGBT damage
Overheating Protection 85 °C Heatsink temperature threshold; fan speed control + alarm/trip
Short‑circuit Protection Internal fast‑acting fuses Coordinated with power section design
EMC Compliance EN 61800‑3, Category C2 Requires external filter for EMC compliance
Mains Contactor Integrated (with break contact) For safe mains isolation
Cooling System Internal forced air cooling Integrated fan with speed monitoring

4. Mechanical & Environmental Specifications

Parameter Value Unit Notes
Net Weight 14.2 kg Base unit without packaging
Dimensions (H×W×D) 457×203×279 mm Standard frame size for 611 series
Ambient Temperature 0–45 °C Operating; derate 1% per 100 m above 1000 m altitude
Storage/Transport Temperature −20 to +45 °C
Installation Altitude ≤1000 m Derate 1% per 100 m above 1000 m
Relative Humidity 5–95% % Non‑condensing
Vibration Resistance 0.5 g 10–150 Hz, IEC 60068‑2‑6
Shock Resistance 15 g 11 ms, IEC 60068‑2‑27
IP Rating IP20 Enclosure protection class
Sound Pressure Level (1m) 70 dB Under standard operating conditions

5. Key Functional & Compliance Details

  • Regenerative Feedback: Converts motor braking energy back to the grid, improving energy efficiency in dynamic applications.
  • Closed-loop Control: Stabilized DC link voltage ensures precise speed/torque control for CNC and motion control systems.
  • Mains Contactor: Integrated contactor with break contact for safe system shutdown and maintenance.
  • Typical Applications: SINUMERIK CNC machines, robotic systems, and high-precision motion control systems requiring regenerative braking.

6. Supplementary Notes

  1. Ambient Temperature: Do not exceed 45°C during operation; derate 1% per 100 m above 1000 m altitude.
  2. Regenerative Operation: Requires proper grid synchronization and compliance with local power quality regulations.
  3. Documentation: Refer to Siemens SIMODRIVE 611 Infeed/Regenerative Feedback Module Manual (Document No. 6SN1145‑1BA02‑0CA2) for complete parameterization and troubleshooting.

Leave a Replay