Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

ACS800-104-0105-3+Q967 Inverter module 3AC 380–480 V (50/60 Hz)

Part Number: ACS800-104-0105-3+Q967
Manufacturer Brands: SIEMENS
Place of Originr: Made in Finland

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
This is a detailed English parameter sheet for the ABB ACS800‑104‑0105‑3 (3‑phase AC‑fed inverter module) with option Q967 (Safe Torque Off, STO), covering core electrical ratings, safety specs, control I/O, physical‑environmental data, and compliance for industrial motor control applications.

Core Electrical Ratings

Parameter Value Notes
Input Voltage (U₁) 3AC 380–480 V (50/60 Hz) Voltage code 3; tolerance ±10%
Rated Input Current (I₁ₙ) 105 A (rms, 3‑phase) At 400 V rated voltage
Rated Output Power (Pₒᵤₜₙ) 55 kW (CT, constant torque); 75 kW (VT, quadratic torque) At 400 V, 50 Hz
Rated Output Current (Iₒᵤₜₙ) 105 A (rms, 3‑phase) Continuous at 40°C ambient
Output Voltage (Uₒᵤₜ) 0–480 V (3‑phase, variable) Matches input voltage range
Output Frequency (fₒᵤₜ) 0–300 Hz (standard); 0–600 Hz (optional) Speed control range
DC Link Voltage (U<sub>DC</sub>) ~530–670 VDC (unloaded) Diode rectifier output
Overload Capacity 110% Iₙ for 60 s; 150% Iₙ for 1 s Per ABB ACS800‑104 design specs
Power Loss (P<sub>loss</sub>) ~2.5 kW (typical, at rated load) Includes control + power stage + Q967
Auxiliary Supply (Uₐᵤₓ) 24 VDC (19.2–28.8 VDC) Control circuit power
Auxiliary Current (Iₐᵤₓ) 3 A (max) For logic, I/O, cooling fans, and Q967

Safety Option (Q967: Safe Torque Off, STO)

Parameter Value Compliance
Safety Function STO (Safe Torque Off) SIL 2 (IEC 61508); PL d (ISO 13849‑1)
STO Circuit Voltage 24 VDC ±10% Isolated dual‑channel input
STO Current Consumption 20 mA per channel Redundant monitoring
Safety Standards EN 61800‑5‑2, IEC 61508, EN ISO 13849‑1 CE marked

Control & I/O Specifications

Parameter Value Details
Control Method Direct Torque Control (DTC); V/f (optional) Speed/torque control with/without encoder
Digital Inputs (XDI) 6 (programmable, 24 VDC) NPN/PNP (DI1–DI5); NPN (DI6); 2.0 kΩ input resistance
Analog Inputs (XAI) 2 (0/4–20 mA or 0/2–10 V) 12‑bit resolution; galvanically isolated
Analog Outputs (XAO) 2 (0/4–20 mA) Max load impedance ≤500 Ω
Relay Outputs (XRO) 3 (programmable) 2 A at 250 VAC/30 VDC
Fieldbus Options Modbus RTU (built‑in); PROFIBUS DP (via K454); CANopen (optional) Q967 works with all fieldbus configs

Physical & Environmental

Parameter Value Limits
Dimensions (H×W×D) 450 × 275 × 400 mm Bookshelf cabinet‑mount profile
Weight 28 kg Steel housing; IP00 protection
Protection Class IP00 Cabinet‑mount only (indoor use)
Ambient Temp (Operation) 0–40°C Derate 1%/°C above 40°C (max 50°C)
Ambient Temp (Storage) -40–70°C No condensation
Relative Humidity 5–95% (non‑condensing) Operation/storage
Altitude ≤ 1000 m Derate 1%/100 m above 1000 m
Vibration/Shock IEC 60068‑2‑6 (vibration); IEC 60068‑2‑27 (shock) 10–500 Hz, 0.5 g (vibration); 15 g (shock, 11 ms)

Protection & Compliance

Feature Details
Overvoltage DC link clamping at 1.3×U<sub>DC</sub> Transient surge protection
Overcurrent Electronic current limiting Trips at >150% Iₙ (sustained)
Short‑Circuit Fuse‑protected input (optional) 50 kA SCCR (400 V)
Standards CE, UL 508C, cUL, IEC 61800‑5‑1 Industrial safety/EMC compliance