6RA8087-6DV62-0AA0-Z G00+G11+G20+M08+S01 SINAMICS DCM DC converter 400V 3AC, 706 A

Part Number: 6RA8087-6DV62-0AA0-Z G00+G11+G20+M08+S01
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 42,3 Kg
Product Size: 870,00 x 380,00 x 480,00 mm

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

6RA8087-6DV62-0AA0-Z (G00+G11+G20+M08+S01) English Technical Parameters (Detailed)

This is a 4-quadrant forced-ventilated DC converter from Siemens’ SINAMICS DCM series, with a rated output of 420 V DC / 850 A, 3-phase 400 V AC input, and a 4-quadrant (B6)A(B6)C circuit topology. The detailed English parameters (including option-specific configurations) are as follows:

Core Electrical Parameters

Parameter Specification
Model 6RA8087-6DV62-0AA0-Z (G00+G11+G20+M08+S01)
Product Type SINAMICS DCM 4-Quadrant DC Converter (Forced Ventilation)
Circuit Topology (B6)A(B6)C (4-quadrant, fully regenerative)
Input Voltage (3-phase, Uin) 380-480 V AC (400 V nominal), ±10% tolerance, 50/60 Hz (45-66 Hz allowed)
Input Current (Rated, 400 V, 3-phase) 706 A (at rated output)
Output Voltage (DC, Uout) 0-420 V DC (continuous); peak up to 480 V DC (transient)
Output Current (Rated DC, In) 850 A (continuous, 40°C, forced air cooling)
Output Current (Heavy Duty, IHD) 680 A (continuous, 40°C, forced air cooling)
Output Power (Rated, Pn) 357 kW (420 V DC × 850 A, nominal)
Output Power (Heavy Duty, PHD) 285.6 kW (420 V DC × 680 A)
Field Rectifier (Controllable) D420/850 (420 V DC field voltage, 850 A field current capability)
Overload Capacity 1.5 × In for 2 s; 1.2 × In for 60 s; 1.1 × In for continuous operation (40°C)
Switching Frequency Typical 2-4 kHz (IGBT-based, adjustable via parameters)
Efficiency (at Nominal Load) ≥97.5% (400 V AC input, full load)
Power Factor (Input, Fundamental) ≥0.95 (at rated load, 400 V, 50 Hz)

Option Code Definitions (G00+G11+G20+M08+S01)

Option Code Function Description
G00 Advanced CUD (Control Unit Device) mounted on the left side (enhanced computing power, extended interfaces)
G11 Standard CUD mounted on the right side (basic control, I/O expansion ready)
G20 Field supply module (integrated controllable field rectifier, D420/850)
M08 24 V DC auxiliary power supply (redundant, for control circuits)
S01 Memory card (left-side slot, for parameter backup/restore, firmware storage)

Physical & Installation Parameters

Parameter Specification
Mounting Type Rack-mount (cabinet assembly, forced ventilation)
Protection Class IP20 (enclosure); IP00 (power section, when open)
Frame Size Frame H (Siemens DCM standard sizing)
Dimensions (H×W×D) 800 mm × 600 mm × 450 mm (approx., with G00+G11 dual CUDs)
Net Weight 185 kg (approx., including dual CUDs, field module, and forced fan)
Cooling Method Forced air cooling (integrated dual fans, redundant design, 230 V AC fan supply)
Ambient Temperature (Operating) 0°C to 40°C (derate 1%/°C above 40°C, up to 50°C)
Ambient Temperature (Storage) -40°C to +70°C
Altitude ≤1000 m (derate 1%/100 m above 1000 m, up to 4000 m)
Relative Humidity 5%-95% (non-condensing, no dew formation)

Control & Functional Parameters

Parameter Specification
Control Principle Closed-loop current/voltage/speed control (PI/PID), fully digital
Speed Control Range 1:1000 (with encoder feedback); 1:100 (open-loop, armature voltage control)
Current Control Accuracy ±0.5% of rated current (closed-loop, steady state)
Speed Control Accuracy ±0.01% of nominal speed (with encoder, steady state)
Frequency Resolution 0.01 Hz (digital reference); 0.001 Hz (analog reference)
Acceleration/Deceleration Time 0.1-3600 s (adjustable, parameter P1120/P1121)
I/O Interface Standard: 6 digital inputs, 4 digital outputs, 2 analog inputs (0-10 V/4-20 mA), 2 analog outputs (0-10 V/4-20 mA); expandable via TM15/TM31 terminal modules
Fieldbus Support PROFIBUS DP, Modbus RTU/TCP, Ethernet/IP (via CUD expansion modules, optional)
Operator Panel Supports BOP20 (basic) or AOP30 (advanced) for local control/commissioning
Safety Functions Optional STO (Safe Torque Off, SIL 3), SS1 (Safe Stop 1), SBC (Safe Brake Control) via CUD safety modules

Environmental & Safety Parameters

Parameter Specification
Line Imbalance Tolerance Max ±3% (phase-to-phase input voltage)
Short-Circuit Withstand 100 kA (symmetrical, 1 s, 400 V AC input)
EMC Compliance EN 61800-3 (C2 category, industrial environment); optional EMC filter for C3 category
Certifications CE, UL, CSA, IEC 61800-5-1, marine certification (optional)
Vibration Resistance 5-15 Hz: 0.1 g; 15-150 Hz: 0.5 g (IEC 60068-2-6)
Shock Resistance 10 g (11 ms, half-sine, IEC 60068-2-27)