Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

ACS880-304-0570A-7+A018 525-690 V AC (±10%), 50/60 Hz (47.5-63 Hz allowed)

Part Number: ACS880-304-0570A-7+A018
Manufacturer Brands: ABB
Place of Originr: Made in Finland

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

ACS880-304-0570A-7+A018 English Technical Parameters (Detailed)

This is a 6-pulse diode supply module (DSU) from ABB’s ACS880-304 series, with +A018 indicating an integrated 6-pulse diode rectifier for cabinet – mounted multi – drive systems (690 V DC link range, 690 V input). It has a rated DC current of 570 A, rated apparent power of 550 kVA (at 690 V, 3 – phase), frame size D7T, and standard IP20 protection for cabinet installation. Below are the comprehensive English parameters:

Core Electrical Parameters

Parameter Specification
Model ACS880-304-0570A-7+A018
Product Type 6-pulse Diode Supply Module (DSU) for ACS880 Multidrive Systems (690 V DC Link, 690 V Input, +A018 = 6-pulse rectifier option)
Input Voltage (Uin) 3-phase, 525-690 V AC (±10%), 50/60 Hz (47.5-63 Hz allowed)
Input Frequency 47.5-63 Hz
DC Link Voltage (Udc) 709-976 V DC (nominal 849 V DC, 690 V range “-7”)
Rated DC Current (Idc, Nominal) 570 A
Apparent Input Power (S) 550 kVA (at 690 V, 3-phase, 6-pulse)
Active Input Power (P, approx.) 540 kW (at full load, cosφ=0.98)
Input Reactor Built – in (standard, for harmonic mitigation)
Power Factor (Fundamental) 0.98 (at full load)
Power Factor (Total) 0.95 (approx., at full load)
Overload Capacity 1.1 × Idc for continuous operation; 1.5 × Idc for 1 min (570 A × 1.5 = 855 A, max. 1 min every 5 min)
EMC Filter Standard C2 category (IEC 61800-3, built – in)
DC Link Capacitor Integrated (for voltage stabilization)
No – load Loss 350 W (approx.)

Physical & Installation Parameters

Parameter Specification
Frame Size D7T
Mounting Type Cabinet – installed (module, IP20 standard)
Protection Class IP20 (module); IP21 (wall – mounted optional)
Enclosure Type NEMA Type 1 (cabinet – mounted)
Dimensions (H×W×D) 1000 mm × 350 mm × 500 mm (approx. 39.4 in × 13.8 in × 19.7 in)
Net Weight 85 kg (approx.)
Cooling Method Forced air cooling (internal fan, 230 V AC fan supply)
Ambient Temperature (Operating) -10°C to +40°C (derate 1%/°C above 40°C, up to 50°C)
Ambient Temperature (Storage) -40°C to +70°C
Altitude ≤1000 m (derate 1%/100 m above 1000 m, up to 4000 m)
Relative Humidity 5% – 95% (non – condensing)

Functional & Safety Parameters

Parameter Specification
Rectifier Type 6 – pulse diode bridge (A018 option, standard for this model)
Harmonic Compliance Meets IEC 61000-3-4 (for 6-pulse rectifiers, with built – in reactor)
Control Interface Compatible with ACS880 inverter units (INU), via DC bus & control links
Safety Functions Overvoltage, undervoltage, overcurrent, overtemperature protection (standard); compatible with Safe Torque Off (STO) of connected INUs
I/O Interface Basic status outputs (ready, fault) for system integration; expandable via DSU – specific I/O modules
Fieldbus Support Compatible with INU communication (Modbus RTU, PROFIBUS DP, Ethernet/IP, etc., via INU modules)
Enclosure Material Steel (coated, for harsh industrial environments)

Environmental & Safety Parameters

Parameter Specification
Line Imbalance Tolerance Max ±3% of nominal phase – to – phase input voltage
Short – Circuit Withstand Capacity 100 kA (symmetrical, 1 s, 690 V AC input)
EMC Compliance EN 61800-3 (C2 category, standard); C3 category (optional with external EMC filter)
Certifications CE, UL, CSA, IEC 61800-5-1
Vibration Resistance 5-15 Hz: 0.1 g; 15-150 Hz: 0.5 g (IEC 60068-2-6)
Shock Resistance 10 g (11 ms, half – sine, IEC 60068-2-27)

Leave a Replay