The ACS880-104-0640A-3 is a single-drive module of ABB ACS880 series industrial drives, configured with option E205 (EMC filter, C2 category) and P922 (safety function module, SIL 3/PL e). Below is the detailed technical parameter sheet:
1. Core Electrical Parameters
| Parameter | Specification |
|---|---|
| Rated Input Voltage | 3-phase, 380–415 V AC; 50/60 Hz
Allowable range: -15% / +10% of rated voltage |
| Rated Input Current | 640 A (at 400 V AC, 50/60 Hz) |
| Rated Output Voltage | 3-phase, 0–input voltage
Voltage regulation: PWM (Pulse Width Modulation) |
| Rated Output Current | 640 A (continuous operation, at 40 °C ambient temperature) |
| Rated Output Power | 355 kW (at 400 V AC, 640 A; cosφ = 0.95) |
| Max Output Power | 390.5 kW (110% of rated power, for 1 min every 10 min cycle) |
| Overcurrent Capacity | 150% of rated current, for 2 s; 110% of rated current, for 60 s |
2. Mechanical & Thermal Parameters
| Parameter | Specification |
|---|---|
| Cooling Method | Forced air cooling (standard configuration; water cooling optional with extra kit) |
| Ambient Temperature | Operating: -10 °C to +40 °C (derating required above 40 °C: 1%/°C up to 50 °C)
Storage: -40 °C to +70 °C |
| Enclosure Protection | IP21 (standard; IP54/IP66 available with customized cabinet) |
| Weight | ~ 685 kg (drive module only; ~ 720 kg with E205 + P922 options) |
| Dimension (H×W×D) | 2200 mm × 1200 mm × 800 mm (approximate, for standalone module) |
| Noise Level | ≤ 75 dB(A) (at 1 m distance, rated load operation) |
3. Option Module Specifications
3.1 Option E205 (EMC Filter, C2 Category)
| Parameter | Specification |
|---|---|
| Function | Reduces electromagnetic interference; complies with IEC 61800-3 C2 category |
| Applicable Scenario | Industrial environments with strict EMC requirements (e.g., near sensitive electronic devices) |
| Voltage Drop | ≤ 2% of rated input voltage (at full load current) |
| Rated Current | 640 A (matches drive module rated current) |
3.2 Option P922 (Safety Function Module)
| Parameter | Specification |
|---|---|
| Safety Certification | SIL 3 (per IEC 61508); PL e (per ISO 13849-1) |
| Safety Functions | STO (Safe Torque Off, Category 0) – primary function
Optional expandable: SS1 (Safe Stop 1), SLS (Safe Limited Speed) |
| Response Time | ≤ 20 ms (STO function activation) |
| Control Voltage | 24 V DC (±15%) for safety circuit power supply |
4. Control & Communication Parameters
| Parameter | Specification |
|---|---|
| Control Modes | V/f control, scalar control, vector control (sensorless / with encoder feedback) |
| Digital Inputs | 8 × 24 V DC (configurable; 2 dedicated for safety circuit when P922 is installed) |
| Analog Inputs | 4 × (0–20 mA / 4–20 mA / 0–10 V) (configurable) |
| Digital Outputs | 6 × relay outputs (250 V AC / 30 V DC, 5 A) |
| Analog Outputs | 2 × (0–20 mA / 4–20 mA) (configurable) |
| Communication Interfaces | Standard: Modbus RTU, PROFIBUS DP, EtherNet/IP (optional: PROFINET IO, DeviceNet) |
5. Protection & Compliance
| Parameter | Specification |
|---|---|
| Protection Functions | Overvoltage, undervoltage, overcurrent, overload, overheating, short circuit, earth fault, motor phase loss protection |
| Compliance Standards | IEC 61800-5-1, IEC 61800-3, CE, UL, CSA, ATEX (for hazardous areas optional) |