This datasheet details the ABB ACS880-104-0140A-3+N5050, a cabinet-mount IP00 3-phase inverter module for multidrive systems, delivering 140A output current and 90kW (125HP) at 690V with Direct Torque Control (DTC), and the N5050 option adds functional safety features for enhanced operational protectionABB Group.
General Information
| Item | Specification |
|---|---|
| Model Number | ACS880-104-0140A-3+N5050 |
| Product Family | ACS880 Series |
| Ordering Code | 3AXD50000046386 (base)+N5050 |
| Frame Size | R6 |
| Mounting Type | Cabinet – mount (for custom cabinet integration) |
| Enclosure Protection | IP00 |
| Control Panel | Control Panel with USB (optional) |
| Main Option | N5050 (Functional Safety Option) |
Electrical Ratings
| Parameter | Value |
|---|---|
| Input Voltage | 3-phase, 525-690V AC (690V nominal), 50/60HzABB Group |
| Output Voltage | 3-phase, 0-Input Voltage, 0-500Hz (varies with control mode) |
| Output Current (Normal Duty) | 140A (90kW/125HP) |
| Output Current (Heavy Duty) | 120A (75kW/100HP) |
| Rated Power | 90kW (125HP normal duty), 75kW (100HP heavy duty) |
| Overload Capacity | 110% for 1 minute, 150% for 3 seconds (typical) |
| Efficiency | >98% (at rated load) |
| Power Factor | >0.98 (at rated load) |
Mechanical Dimensions & Weight
| Dimension | Value |
|---|---|
| Height | 550 mm (21.65 in) |
| Width | 350 mm (13.78 in) |
| Depth | 300 mm (11.81 in) |
| Net Weight | 45 kg (99 lbs) |
Communication & Control
| Feature | Specification |
|---|---|
| Control Method | Direct Torque Control (DTC)ABB Group |
| Standard Protocols | Modbus RTU, PROFIBUS DP, Ethernet/IP (optional) |
| I/O Configuration | 6 digital inputs, 2 relay outputs, 2 analog inputs, 1 analog output (configurable) |
Protection & Safety (Including N5050 Option)
| Protection Feature | Description |
|---|---|
| Overcurrent Protection | Trips when output current exceeds the set limit |
| Overvoltage Protection | Activates when DC bus voltage is too high |
| Undervoltage Protection | Triggers when input voltage is below the minimum threshold |
| Overtemperature Protection | Shuts down the drive if heatsink temperature is excessive |
| Short Circuit Protection | Guards against output short circuits |
| Integrated Safety (N5050) | Adds STO (Safe Torque Off) and other functional safety functions for higher – level safety complianceABB Group |
Environmental Conditions
| Condition | Range |
|---|---|
| Operating Temperature | 0°C to +40°C (32°F to 104°F); derate 1% per 10°C above 40°C |
| Storage Temperature | -40°C to +70°C (-40°F to 158°F) |
| Relative Humidity | 5% to 95% (non – condensing) |
| Altitude | Up to 1000m (3300ft) without derating; derate 1% per 100m above 1000m |
| Vibration | 0.5g (5Hz to 150Hz) |
-150x150.png)