This datasheet describes the ABB ACS880-01-206A-3, a 3-phase wall-mounted AC drive with 206A output current and 110kW (148HP) rating at 400V, featuring Direct Torque Control (DTC) for precise speed and torque control, ideal for pumps, fans, conveyors, and compressors requiring reliable and efficient operation.
General Information
| Item | Specification |
|---|---|
| Model Number | ACS880-01-206A-3 |
| Product Family | ACS880 Series |
| Ordering Code | 3AUA0000108028 |
| Frame Size | R7 |
| Mounting Type | Wall-mounted |
| Enclosure Protection | IP21 (UL Type 1) with conformal coating |
| Control Panel | Assistant Bluetooth (optional) |
| Standard Feature | Built-in choke, EMC filter, brake chopper, Safe Torque Off (STO) |
Electrical Ratings
| Parameter | Value |
|---|---|
| Input Voltage | 3-phase, 380-480V AC (400V nominal), 50/60Hz |
| Output Voltage | 3-phase, 0-Input Voltage, 0-500Hz (adjustable via control mode) |
| Output Current (Normal Duty) | 206A (110kW/148HP at 400V) |
| Output Current (Heavy Duty) | 169A (90kW/120HP at 400V) |
| Output Current (Light Overload) | 196A (110kW/148HP at 400V) |
| Overload Capacity | 150% for 1 minute, 110% for continuous |
| Efficiency | >97% (at rated load) |
| Power Factor | >0.98 (at rated load) |
| Power Dissipation | 1834W (at 100% load) |
| Standby Loss | 42W |
| Apparent Power Output | 143kVA |
Mechanical Dimensions & Weight
| Dimension | Value |
|---|---|
| Height | 879 mm (34.6 in) |
| Width | 283 mm (11.18 in) |
| Depth | 365 mm (14.37 in) |
| Net Weight | 28 kg (61.7 lbs) |
Communication & Control
| Feature | Specification |
|---|---|
| Control Method | Direct Torque Control (DTC) |
| Standard Protocols | Modbus RTU (built-in); PROFIBUS DP, PROFINET IO, DeviceNet (optional) |
| I/O Configuration | 6 digital inputs, 3 relay outputs, 2 analog inputs, 2 analog outputs (configurable) |
Protection & Safety
| Protection Feature | Description |
|---|---|
| Overcurrent Protection | Trips when output current exceeds the set threshold |
| Overvoltage Protection | Activates when DC bus voltage is overly high |
| Undervoltage Protection | Triggers when input voltage is below the minimum limit |
| Overtemperature Protection | Shuts down the drive if heatsink temperature is too high |
| Short Circuit Protection | Protects against output short circuits |
| STO Function | Safe Torque Off (SIL3 as per IEC61511, SILCL3 as per IEC62061, PLe ISO13849-1) |
Environmental Conditions
| Condition | Range |
|---|---|
| Operating Temperature | -15°C to +40°C (5°F to 104°F); derate 1% per 10°C above 40°C |
| Storage Temperature | -40°C to +70°C (-40°F to 158°F) |
| Relative Humidity | 5% to 95% (non-condensing) |
| Altitude | Up to 1000m (3300ft) without derating; derate 1% per 100m above 1000m |
| Vibration | 0.5g (5Hz to 150Hz) |