Product Type: Basic Line Module (Rectifier, Non-Regenerative) | Status: Active (PM300) | Cooling: Internal Forced-Air Cooling | Frame: Booksize | Core Use: 3AC mains to 600V DC link for S120 multi-axis drive systems, 100kW rated power
Input: 3AC 380–480 V, 50/60 Hz | Output: 600 V DC (unregulated) | Rated DC Output Current: 167 A | Rated Power: 100 kW
1. Electrical Ratings
| Parameter | Value | Notes |
|---|---|---|
| Input Voltage (3AC) | 380 … 480 V AC | 50/60 Hz, nominal 400V AC |
| Input Frequency | 50 / 60 Hz | Standard industrial mains |
| DC Link Output Voltage | ~600 V DC | Unregulated (≈1.35 × input AC line voltage) |
| Rated DC Output Current (IN) | 167 A | Continuous (S1 duty, 40°C ambient) |
| Rated Input Power | 100 kW | At nominal input/output |
| Max Peak DC Current | > 2× IN | Short-term overload (per system design) |
| Power Loss (Typ./Max) | ~0.3 kW / ~0.5 kW | At rated load |
| 24 V DC Aux Supply | 24 V DC (-15% / +20%) | 20.4–28.8 V DC, max 0.5 A |
| Insulation Class | F (155 °C) | Standard for power electronics |
| Dielectric Test Voltage | 3.0 kV AC (1 min) | Input/DC link/aux to ground |
| Safety Integrated | STO (Safe Torque Off) | SIL 2 (IEC 61508), PL d (EN ISO 13849-1), Cat. 3 |
| EMC Compliance | IEC 61800-3, EN 61000-6-2/-3 | CE, cULus, RoHS |
| Max Mains Cable Length | Shielded: 50 m; Unshielded: 100 m | Extend with line reactor/filter |
2. Mechanical & Environmental Data
| Parameter | Value | Notes |
|---|---|---|
| Dimensions (H×W×D) | 380 mm × 150 mm × 270 mm | 14.96 × 5.91 × 10.63 in (Booksize frame) |
| Net Weight | ~18 kg | ~39.7 lb |
| Degree of Protection | IP20 (front), IP00 (rear) | UL open type |
| Sound Pressure Level (1m) | < 65 dB (A) | At rated load |
| Ambient Temp (Operation) | 0 … +40 °C | Derate 1% per 1 K above 40 °C |
| Storage Temperature | -40 … +85 °C | |
| Installation Altitude (No Derating) | ≤ 1000 m | 1% derate per 100 m above 1000 m |
| Humidity | 5 … 95% RH | Non-condensing |
| Terminals (Mains/DC Link) | M6/M8 bolt | Conductor cross-section: 16 … 50 mm² (6 … 2/0 AWG) |
| PE Connection | M8 screw | Low-impedance ground required |
| DC Link Capacitance | Internal | Integrated for DC link stability |
3. Key Features & Compatibility
- Non-Regenerative Rectifier: Converts 3AC mains to stable 600V DC for S120 motor modules; no regenerative braking (use ALM for regeneration)
- Booksize Design: Compact, fits standard S120 cabinet layouts; DRIVE-CLiQ for control unit (CU320-2/CU310-2) communication
- High Power Density: 100kW in booksize frame, ideal for multi-axis machine tools, packaging, printing, textile machinery
- Robust Cooling: Internal forced-air cooling with optimized airflow for high-duty industrial operation
- Compatibility: For SINAMICS S120 drive systems; pairs with 6SL3120/6SL3130 motor modules (total DC link current ≤167A)
- Safety & Compliance: STO, EMC, and global safety standards for industrial use
4. Installation & Application Notes
- Mount vertically (top/bottom airflow) in a ventilated cabinet; maintain clearances per S120 manual
- Derate for high altitude (>1000 m), high ambient temp (>40 °C), or continuous overload
- Use shielded mains cable for EMC compliance; bond shield at both ends
- Match to S120 Control Unit (CU) with matching firmware version (V4.7 HF8+ recommended)
- Do not exceed total DC link current of connected motor modules (≤167A continuous)
- Technical data subject to change; always verify with latest Siemens documentation

-236x300.png)