Product Type: Fan Transformer for SINAMICS Basic Line Modules | Status: Active | Application: Cooling fan power supply for 500–690V 3AC 50/60Hz line modules | Compliance: RoHS, IEC 61558 (safety standard for power transformers)
1. Core Electrical Ratings
| Parameter | Value | Notes |
|---|---|---|
| Input Voltage | 3AC 500 … 690 V, 50/60 Hz | Nominal for high-voltage line modules |
| Input Frequency | 50/60 Hz | Standard industrial mains |
| Output (Fan Supply) | Typically 3AC low-voltage (e.g., 230V/400V) | Matches fan rated voltage for line module cooling |
| Insulation Class | F (155 °C) | Standard for industrial power electronics |
| Dielectric Test | 3.0 kV AC (1 min) | Primary/secondary/ground |
| Operating Temp | -20 … +45 °C | Derate for high ambient |
| Storage Temp | -40 … +70 °C | |
| Humidity | 5 … 95% RH | Non-condensing |
| Altitude (No Derating) | ≤ 1000 m | 1% derate per 100 m above |
2. Mechanical & Physical Data
| Parameter | Value | Notes |
|---|---|---|
| Dimensions (Typ.) | ~56 × 89 mm (L×W) | Compact for chassis mounting |
| Net Weight (Typ.) | ~1.0 kg | Lightweight, low-profile design |
| Mounting | Chassis-mounted (screw/clip) | Integrated with line module cooling system |
| Coating | 3C2 (IEC 60721-3-3) | Harsh environment resistance |
| Terminals | Screw terminal / fast-on | Secure, low-impedance connections |
3. Key Features & Compatibility
- Fan Power Supply: Dedicated transformer for cooling fans of SINAMICS 500–690V Basic Line Modules (e.g., 6SL3353-1AG41-8DA1)
- High Reliability: Industrial-grade insulation, wide temp/humidity range, RoHS compliant
- Plug-and-Play: Direct replacement for original fan transformers in Siemens drive systems
- EMC Compatibility: Designed to meet IEC 61800-3 EMC standards for drive systems
- Safety: Complies with IEC 61558 for power transformers, safe for industrial use
4. Installation & Application Notes
- Mount vertically/horizontally per line module manual; ensure airflow for cooling
- Match input voltage to line module mains (500–690V 3AC)
- Use shielded cables for fan output to reduce EMI
- Verify fan voltage/current rating matches transformer output
- Do not exceed rated input voltage/frequency; protect with appropriate fuses
- Technical data subject to change; always verify with latest Siemens documentation
-150x150.png)