Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA7093-4KV62-0-Z K11+K01+G95 SIMOREG DC Master 690 V 3 AC, 1244 A

Part Number: 6RA7093-4KV62-0-Z K11+K01+G95
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
Product Category: SIMOREG DC Master 4-Quadrant DC Drive (Rectifier)

Brand: Siemens

Model Number: 6RA7093-4KV62-0-Z K11+K01+G95

Document Version: V1.0 (Industrial Standard)

Applicable Standards: IEC 61800-5-1, UL 508C, CSA C22.2 No.14, CE (LVD/EMC), RoHS

Lifecycle Status: Discontinued (since 2022-01-20); Successor: 6RA8093-4KV62-0AA0


1. Core Electrical Specifications

Parameter Rating Unit Notes
Input Voltage (3-Phase AC) 690 V Nominal; Range: 600–750 V AC, 50/60 Hz ±5 Hz
Input Current (Nominal) ~1326 A At full load, 690 V AC input
Armature Output Voltage 690 V DC Max; Adjustable 0–690 V DC
Armature Output Current (Continuous) 1600 A @ 40°C ambient; 4-quadrant operation (B6A/B6C bridge)
Armature Output Current (US Rating) 1190 A UL/CSA rated continuous
Armature Output Power (Max) ~1104 kW 690 V DC × 1600 A (theoretical)
Field Output Voltage 325 V DC Adjustable; Derived from input
Field Output Current (Max) 40 A Controllable field rectifier (D690/1600)
Control Supply Voltage 230 V AC 1-phase, 50/60 Hz
DC Bus Voltage ~960 V DC Unregulated; Overvoltage trip >1050 V DC
Switching Frequency 125 Hz Line-commutated thyristor bridge
Control Modes Armature Voltage Control, Speed Control (Closed-Loop), Torque Control, Field Weakening 4-quadrant regenerative braking

2. Mechanical Specifications

Parameter Value Unit Notes
Enclosure Type IP20 / NEMA 1 Indoor, dust-protected
Mounting Floor/Panel Mount Standard base frame
Dimensions (H×W×D) ~1200×600×800 mm Approx. (including terminal covers)
Net Weight ~145 kg Without options
Gross Weight ~160 kg Packaged
Cooling Forced Air (Fan-Cooled) Dual fans; Airflow: ~1200 m³/h
Terminal Type Copper Lug (Heavy-Duty) Suitable for 250–500 kcmil cables

3. Operational Specifications

3.1 Environmental Ratings

Condition Min Max Unit Notes
Ambient Operating Temp 0 40 °C 50°C with 10% current derate
Storage Temp -40 70 °C No condensation
Relative Humidity 5 95 % Non-condensing
Altitude 0 1000 m 1% derate per 100 m above 1000 m
Vibration 2.9 m/s² 5–150 Hz, IEC 60068-2-6
Shock 15 g 11 ms half-sine, IEC 60068-2-27

3.2 Control Performance

Parameter Specification Unit
Speed Regulation (Closed-Loop) ±0.01 % With encoder feedback
Torque Response Time <10 ms 0–100% rated torque
Accel/Decel Time 0.1–3600 s Programmable
Speed Range (Field Weakening) 1:10 Standard; up to 1:20 with option
Analog Inputs 0–10 V DC, 4–20 mA 2 channels, 12-bit resolution
Analog Outputs 0–10 V DC, 4–20 mA 2 channels, 12-bit resolution
Digital Inputs 24 V DC (Sink/Source) 8 channels, opto-isolated
Digital Outputs 24 V DC / 2 A 4 channels, relay/transistor
Encoder Input TTL/HTL, 5–24 V DC Up to 100 kHz

4. Protection Features

Protection Type Specification
Overcurrent (Armature) Instantaneous trip at 200% rated (0.1s); 150% (1s)
Overvoltage (DC Bus) Trip >1050 V DC; Auto shutdown
Undervoltage (DC Bus) Trip <700 V DC; Auto shutdown
Overheating Thyristor heatsink, fan failure, motor thermistor (PTC/NTC)
Earth Fault Residual current detection; Trip <500 mA
Phase Loss Input/output phase loss; Alarm + shutdown
Short Circuit Thyristor short-circuit; Instantaneous shutdown (no damage)
Motor Thermal Built-in thermal model + external thermistor input
Surge Input transient (2 kV); IEC 61000-4-5
Field Overcurrent Trip at 120% rated field current

5. Communication & Options (K11+K01+G95)

Option Code Description Interface/Protocol
K01 Basic Operator Panel (BOP) Local keypad + LCD; Parameter setup/monitoring
K11 PROFIBUS DP Communication Module PROFIBUS DP V0/V1; Baud rate 9.6 kbps–12 Mbps
G95 Extended I/O Module Additional 8 DI + 4 DO + 2 AI + 2 AO; Opto-isolated
Standard RS-232/RS-485 Modbus RTU; Local programming
Optional Ethernet/IP, DeviceNet Via add-on adapters

6. Efficiency & Power Quality

Parameter Value Unit Notes
Full-Load Efficiency ≥97.5 % 690 V AC input, 100% load
Partial-Load (50%) Efficiency ≥97.0 % 690 V AC input, 50% load
Input Power Factor ≥0.92 Full load, no line reactor
THD (Input Current) <10 % With 3% line reactor; <15% without

7. Compliance & Certifications

  • IEC 61800-5-1: Adjustable Speed Electrical Power Drive Systems
  • UL 508C: Industrial Control Equipment
  • CSA C22.2 No.14: Industrial Control Equipment
  • CE Mark: Low Voltage Directive (LVD), EMC Directive
  • RoHS 2: 2011/65/EU
  • ATEX (Optional): Ex nA IIC T4 Gc (Non-Sparking)

8. Ordering Code Breakdown (6RA7093-4KV62-0-Z K11+K01+G95)

Segment Code Description
6RA70 SIMOREG DC Master Series
93 Frame Size: 1600 A armature current
4 4-quadrant operation (B6A/B6C bridge)
KV62 Input: 3AC 690 V, 50/60 Hz; Output: 690 V DC
0 Standard configuration (no special factory options)
Z Option code suffix
K01 Basic Operator Panel (BOP)
K11 PROFIBUS DP communication module
G95 Extended I/O module

Leave a Replay