Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA7097-4KV62-0-Z K11+K01+G95+D64 SIMOREG DC Master 690 V 3 AC, 2155 A

Part Number: 6RA7097-4KV62-0-Z K11+K01+G95+D64
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 145,388 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
Product Category: SIMOREG DC Master 4-Quadrant DC Drive (Thyristor Rectifier)

Brand: Siemens

Model Number: 6RA7097-4KV62-0-Z K11+K01+G95+D64

Document Version: V1.0 (Industrial Standard)

Applicable Standards: IEC 61800-5-1, UL 508C, CSA C22.2 No.14, CE (LVD/EMC), RoHS 2

Lifecycle Status: Discontinued; Successor: 6RA8097-4KV62-0AA0 (SINAMICS DCM)


1. Core Electrical Specifications

Parameter Rating Unit Notes
Input Voltage (3-Phase AC) 690 V Nominal; Operating Range: 600–750 V AC, 50/60 Hz ±5 Hz
Input Current (Nominal, Full Load) ~2160 A At 690 V AC input, 100% load
Armature Output Voltage (Max) 690 V DC Adjustable 0–690 V DC (4-quadrant B6A/B6C bridge)
Armature Output Current (Continuous) 2600 A @ 40°C ambient; 4-quadrant regenerative operation
Armature Output Current (UL/CSA Rating) 1876 A Continuous duty per North American standards
Armature Output Power (Max) ~1794 kW 690 V DC × 2600 A (theoretical)
Field Output Voltage 325 V DC Adjustable; Derived from input AC
Field Output Current (Max) 40 A Controllable field rectifier (D690/2600)
Control Supply Voltage 230 V AC 1-phase, 50/60 Hz
DC Bus Voltage (Unregulated) ~960 V DC Overvoltage trip threshold: >1050 V DC
Switching Frequency 125 Hz Line-commutated thyristor bridge (no IGBT PWM)
Control Modes Armature Voltage, Closed-Loop Speed, Torque, Field Weakening 4-quadrant bidirectional power flow

2. Mechanical Specifications

Parameter Value Unit Notes
Enclosure Type IP20 / NEMA 1 Indoor, dust-protected (non-weatherproof)
Mounting Floor/Panel Mount Standard base frame with mounting holes
Dimensions (H×W×D) ~1200×600×800 mm Approx. (including terminal covers & fans)
Net Weight ~160 kg Without optional accessories
Gross Weight ~175 kg Packaged with standard foam & pallet
Cooling Forced Air (Dual Fans) Airflow: ~1600 m³/h; Fan failure alarm & trip
Terminal Type Heavy-Duty Copper Lug Suitable for 300–500 kcmil (70–120 mm²) cables

3. Operational Specifications

3.1 Environmental Ratings

Condition Min Max Unit Notes
Ambient Operating Temp 0 40 °C 50°C with 10% current derate
Storage Temperature -40 70 °C No condensation, no corrosive gases
Relative Humidity 5 95 % Non-condensing
Altitude 0 1000 m 1% derate per 100 m above 1000 m
Vibration Resistance 2.9 m/s² 5–150 Hz, IEC 60068-2-6
Shock Resistance 15 g 11 ms half-sine, IEC 60068-2-27

3.2 Control Performance

Parameter Specification Unit
Speed Regulation (Closed-Loop) ±0.01 % With encoder feedback (TTL/HTL)
Torque Response Time <10 ms 0–100% rated torque
Accel/Decel Time Range 0.1–3600 s Programmable via BOP/fieldbus
Speed Range (Field Weakening) 1:10 Standard; up to 1:20 with advanced tuning
Analog Inputs 0–10 V DC, 4–20 mA 2 channels (standard) + 2 channels (G95)
Analog Outputs 0–10 V DC, 4–20 mA 2 channels (standard) + 2 channels (G95)
Digital Inputs 24 V DC (Sink/Source) 8 channels (standard) + 8 channels (G95)
Digital Outputs 24 V DC / 2 A 4 channels (standard) + 4 channels (G95)
Encoder Input TTL/HTL, 5–24 V DC Up to 100 kHz pulse frequency

4. Protection Features

Protection Type Specification
Armature Overcurrent Instantaneous trip at 200% rated (0.1s); 150% (1s)
DC Bus Overvoltage Trip >1050 V DC; auto shutdown & fault log
DC Bus Undervoltage Trip <700 V DC; auto shutdown
Overheating Thyristor heatsink, fan failure, motor PTC/NTC thermistor input
Earth Fault Residual current detection; trip <500 mA
Phase Loss Input/output phase loss; alarm + immediate shutdown
Short Circuit Thyristor short-circuit; instantaneous shutdown (no module damage)
Motor Thermal Built-in thermal model + external thermistor input
Input Surge 2 kV transient protection; IEC 61000-4-5
Field Overcurrent Trip at 120% rated field current (48 A)

5. Communication & Options (K11+K01+G95+D64)

Option Code Description Interface/Protocol
K01 Basic Operator Panel (BOP) Local keypad + LCD; parameter setup, monitoring, fault reset
K11 PROFIBUS DP Communication Module PROFIBUS DP V0/V1; baud rate 9.6 kbps–12 Mbps
G95 Extended I/O Module +8 DI, +4 DO, +2 AI, +2 AO; all opto-isolated
D64 Extended Field Supply Module Boosted field current/power; supports high-field motors
Standard RS-232/RS-485 Modbus RTU; local programming & data logging
Optional Ethernet/IP, DeviceNet Via add-on communication adapters

6. Efficiency & Power Quality

Parameter Value Unit Notes
Full-Load Efficiency ≥97.5 % 690 V AC input, 100% load
Partial-Load (50%) Efficiency ≥97.0 % 690 V AC input, 50% load
Input Power Factor ≥0.92 Full load, no line reactor
Input Current THD <10 % With 3% line reactor (e.g., 6RY1703-0DA02); <15% without

Leave a Replay