6ES7136-6RA00-0BF0 SIMATIC DP 24.. 230 V AC

Part Number: 6ES7136-6RA00-0BF0
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 0,067 Kg
Product Size: 8,00 x 6,8 x 2,9 cm

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

Core Electrical Specifications

Parameter Value
Model 6ES7136-6RA00-0BF0
Product Type SIMATIC DP fail-safe relay output module (F-RQ) for ET 200SP distributed I/O system
Output Configuration 1 relay output with 2 normally open (NO) contacts
Load Voltage Range 24 V DC; 24-230 V AC
Rated Switching Current (Resistive Load) 5 A DC/AC (max)
Thermal Continuous Current 5 A (max)
Min Switching Current 1 mA (resistive); 10 mA (after 300 mA)
Relay Coil Voltage 24 V DC (20.4-28.8 V DC permissible)
Max Relay Coil Current 70 mA DC
Power From Backplane Bus 100 mW
Typical Power Loss 1 W
Isolation Test Voltage 2545 V DC (2 s)
Switching Capacity (Lamp Load) 25 W (max)
Relay Approvals UL 508, Pilot Duty B300/R300

Safety & Functional Specifications

Parameter Value
Safety Integrity Level (SIL) SIL 3 (per IEC 61508:2010)
Performance Level (PL) PL E (per ISO 13849-1:2008)
External Protection Requirement 6 A circuit breaker (per manual)
Min Switching Voltage 19 V (DC/AC)
Cable Length (Load Contacts) Max 500 m (shielded); 300 m (unshielded)
Control Cable Length Max 10 m
Configurable With STEP 7 V5.5 SP4+; TIA Portal V13+

Mechanical & Environmental Specifications

Parameter Value
Module Width 20 mm
Net Weight 0.07 kg (70 g)
Mounting DIN rail (ET 200SP base unit required)
Operating Temperature 0-50°C (non-condensing)
Storage Temperature -25-70°C
Relative Humidity 5%-95% (non-condensing)
Altitude Up to 2000 m (derate above 1000 m)
Status Indicators LEDs for module power, output state, and diagnostics

Key Features

  1. Fail-Safe Design: Supports safe shutdown and diagnostics for critical applications.
  2. Redundant Contacts: 2 NO contacts per output for high availability.
  3. Backplane Power Efficiency: Low 100 mW bus power draw minimizes system load.
  4. Wide Load Compatibility: Works with 24 V DC sensors and 230 V AC actuators.
  5. Integrated Diagnostics: Monitors output state, overcurrent, and coil integrity.

Leave a Replay