Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

DCS550-S01-0900-05-00-00 DCS550 DC Drive, Single‑Bridge 2‑Quadrant

Part Number: DCS550-S01-0900-05-00-00
Manufacturer Brands: ABB
Place of Originr: Made in Finland

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

Core Electrical Specifications

Parameter Value Notes
Product Type DCS550 DC Drive, Single‑Bridge 2‑Quadrant 2‑quadrant operation (forward motoring / reverse braking)
Rated Input Voltage 3‑phase AC 525 V Nominal; 50/60 Hz
Input Voltage Range 3‑phase AC 230 V – 525 V -15% / +10% tolerance
Rated Armature Current (Continuous) 900 A DC 40°C, 100% duty cycle
Peak Armature Current 1350 A DC 1.5 × rated, max 2 seconds
Rated Armature Output Voltage 525 V DC At rated input voltage
Rated Output Power 472.5 kW Calculated: 525 V × 900 A
Integrated Field Supply 3‑phase controllable Built‑in, no external unit needed
Rated Field Current Range 2 – 35 A DC Adjustable; max 35 A continuous
Rated Field Voltage 310 V DC Max field output voltage
Typical Power Loss ~32 kW At full rated load (estimated)
Control Modes Speed, Torque, Current Closed‑loop / open‑loop
Speed Control Accuracy ±0.01% (with encoder) High‑precision speed regulation

Power & Thermal Specifications

Parameter Value Notes
Cooling Method Forced air (internal fan) 115/230 V AC fan supply
Ambient Temperature (Operation) 0°C – 40°C Derate 2.5% per °C above 40°C
Ambient Temperature (Storage) -40°C – 70°C Non‑condensing
Relative Humidity 5% – 95% Non‑condensing
Altitude ≤ 1000 m Derate 1% per 100 m above 1000 m
Cooling Airflow ~2800 m³/h Forced ventilation requirement (estimated)
Sound Pressure Level ~72 dB(A) At 1 m distance (estimated)

Mechanical & Protection

Parameter Value Notes
Protection Class IP00 (open chassis) For cabinet installation
Dimensions (H×W×D) ~600 mm × 350 mm × 350 mm Without terminal covers (estimated)
Net Weight ~65 kg Unpacked (estimated)
Mounting Vertical rack‑mount / free‑standing Vertical orientation only
Isolation Test Voltage 2.5 kV AC Power section to ground
Short‑Circuit Protection Electronic current limiting + fast fuses Adjustable trip thresholds
Overvoltage Protection Varistor + active clamping Input & output sides
Overtemperature Protection Heatsink thermal sensor + shutdown Automatic fault protection
Safety Feature Safe Torque Off (STO) Standard, certified safety function

Control & Communication Interfaces

Interface Details
Analog Inputs 4 × 0–10 V / 0–20 mA Isolated, 12‑bit resolution
Analog Outputs 3 × 0–10 V / 0–20 mA Isolated, 12‑bit resolution
Digital Inputs 8 × 24 V DC PNP/NPN configurable
Digital Outputs 5 × 24 V DC, 2 A Solid‑state (relay‑free)
Encoder Feedback Supports TTL / HTL / SinCos encoders High‑resolution position feedback
Fieldbus Options (Pluggable) PROFIBUS DP, CANopen, DeviceNet, Modbus RTU, Ethernet/IP, Modbus TCP, EtherCAT, PROFINET Optional modules
Built‑in PID Controller Standard For process control (tension, pressure, etc.)
Programming Custom AP (Application Programming) 16 function b

Leave a Replay