Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

DCS550‑S02‑0680‑05‑00‑00 ABB DCS550 DC Drive regenerative dual converter

Alternate PN: DCS550‑S02‑0680‑05‑00‑00
Manufacturer Brands: ABB
Place of Originr: Made in Finland

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

1. General Identification

Item Specification
Model DCS550‑S02‑0680‑05‑00‑00
Product Series ABB DCS550 DC Drive
Topology 4‑quadrant, fully regenerative dual converter
Frame Size F3
Protection Degree IP00 (open chassis)
Cooling Forced air cooling
Certifications CE, cULus, EMC compliant with EN 61800‑3

2. AC Mains Input Data

Parameter Value
Input Type 3‑phase AC
Nominal Voltage 400 VAC
Voltage Range 230 … 525 VAC (‑15% / +10%)
Frequency 50 / 60 Hz (auto‑sensing)
Short‑circuit Withstand 10 kA for 1 s
Recommended Mains Fuse 800 A, 690 V class

3. DC Armature Output Data

Parameter Value
Rated Armature Current 680 A continuous
Maximum Peak Current 1700 A (250% of rated)
Peak Duration 60 seconds
Medium Overload 150% × In for 10 min
Rated Armature Voltage Up to 490 VDC (at 525 VAC input)
Maximum Armature Voltage Up to 510 VDC
Rated Output Power 333.2 kW (at 490 VDC, 680 A)
Maximum Output Power 346.8 kW (at 510 VDC, 680 A)
Current Ripple < 5% typical
Voltage Ripple < 1% typical
Control Principle Phase‑controlled thyristor converter

4. Field Exciter Data

Parameter Value
Field Supply Integrated 3‑phase controlled rectifier
Rated Field Current 35 A continuous
Maximum Field Current 40 A
Field Voltage Range 0 … 420 VDC
Control Mode Constant current / field weakening
Field Weakening Ratio Up to 1:10 (motor‑dependent)

5. Performance Characteristics

Parameter Value
Speed Regulation (with encoder) ±0.01% of base speed
Speed Regulation (without encoder) ±0.5% of base speed
Current Loop Bandwidth ≥ 1000 Hz
Speed Loop Bandwidth ≥ 200 Hz
Current Rise Time < 1 ms
Control Modes Speed control, torque control, tension control, field weakening

6. Control & Interfaces

Interface Specification
Analog Inputs 4 × 15‑bit (0–10 V, ±10 V, 0–20 mA)
Analog Outputs 3 × 11‑bit (0–10 V, ±10 V)
Digital Inputs 8 × 24 VDC (sink/source configurable)
Digital Outputs 5 × relay / transistor outputs
Encoder Input Incremental encoder: 5 V / 24 V, A/B/Z
Tachometer Input 0 … 10 V DC
Motor Temperature 1 × PTC input
Fieldbus Slots 2 slots
Supported Protocols Profibus DP, Ethernet/IP, PROFINET, Modbus TCP/RTU, CANopen, DeviceNet
Commissioning Tools DriveWindow Light, Adaptive Programming (AP)

7. Environmental & Mechanical Data

Parameter Value
Ambient Operating Temp 0 °C … +40 °C
Storage Temp −20 °C … +60 °C
Humidity 5–95% RH, non‑condensing
Altitude ≤ 1000 m (derate 1% per 100 m above)
Dimensions (W × H × D) 550 × 270 × 345 mm
Weight 32 kg

8. Model Code Explanation

Code Segment Meaning
DCS550 Drive series
S0 Standard chassis drive
2 4‑quadrant regenerative operation
0680 Rated armature current: 680 A
05 Supply voltage range: 230–525 VAC
00‑00 No factory‑mounted options