This datasheet specifies the Siemens SINAMICS G120XA 6SL3220-2YD48-0CB0, a 132 kW (177 hp) low-overload (LO) AC drive for 380–480 V 3AC industrial pump/fan applications, with integrated BOP‑2 and C3 filter.
Core Product & Ordering Info
| Item | Detail |
|---|---|
| Part Number | 6SL3220-2YD48-0CB0 |
| Product Type | SINAMICS G120XA AC Drive (3AC, 132 kW, LO) |
| Rated Power (400 V LO) | 132 kW (177 hp) |
| Frame Size | FSF (H×W×D: 709 × 305 × 360 mm) |
| Net Weight | 68 kg |
| Cooling | Integrated fan air‑cooled |
| Mounting | Vertical wall‑mount |
| Integrated Options | Integrated BOP‑2; C3 EMI filter; 6DI/4DQ/2AI/2AQ/1Mot_t |
Electrical Specifications
| Parameter | Value |
|---|---|
| Input Voltage | 3AC 380–480 V (-20%/+10%) |
| Input Frequency | 47–63 Hz |
| Input Current (LO) | 242 A (400 V) |
| Output Voltage | 0–input V (3AC, PWM) |
| Output Current (LO) | 242 A (continuous); 266 A (110% for 60 s/600 s) |
| Output Frequency | 0–590 Hz |
| Switching Frequency | 4 kHz (adjustable 2–16 kHz) |
| Control Voltage | 24 V DC (auxiliary) |
| Fieldbus | MODBUS RTU, BACnet MS/TP, USS |
Mechanical & Environmental
| Parameter | Value |
|---|---|
| IP Rating | IP20 (front panel) |
| Operating Temperature | -20–45 °C (-4–113 °F) |
| Storage/Transport | -40–70 °C (-40–158 °F) |
| Relative Humidity | ≤95% (non‑condensing, 0–40 °C) |
| Altitude | ≤1000 m (derate 1% per 100 m above 1000 m, max 4000 m) |
| Vibration/Shock | Compliant with IEC 60721‑3‑3 (class 3C2) |
| Filter | Integrated C3 EMI/RFI filter (Class A) |
| Coating | Standard board coating (Class 3C2) |
Interfaces & Protections
| Interface/Protection | Configuration |
|---|---|
| Digital I/O | 6 DI (24 V DC), 4 DQ (relay/open‑collector) |
| Analog I/O | 2 AI (0–10 V/4–20 mA), 2 AQ (0–10 V/4–20 mA) |
| Motor Temp Input | 1 Mot_t (PTC/KTY84‑130) |
| Operator Panel | Integrated BOP‑2 (monochrome LCD, 10‑key keypad) |
| Protections | Overcurrent, overvoltage, undervoltage, overtemperature, short‑circuit, EMC filtering |
| Certifications | CE, cULus, EAC, KCC, RCM, RoHS/REACH/WEEE compliant |
Key Features
- Pump/Fan Optimization: Low‑overload (LO) design for continuous‑duty pump/fan loads.
- Integrated Filter: C3 filter reduces EMI/RFI emissions for industrial grids.
- Multiple Fieldbuses: MODBUS RTU/BACnet MS/TP/USS for seamless system integration.
- Built‑in HMI: BOP‑2 enables local parameterization, control, and diagnostics.
- Robust Design: Class 3C2 coating and IP20 rating for harsh industrial environments.