EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
This is a 3‑phase, 480‑V class machinery drive with 37 kW / 50 HP rating, frame size D, IP20.

Core Electrical Ratings

Parameter Value Notes
Model ACS850‑04‑061A‑5
Supply Voltage 3‑phase 380–500 V AC, +10% / -15% 50/60 Hz ±5%
Nominal Input Current (I₁N) 31 A RMS at 40 °C, with built‑in mains choke
Nominal Output Current (I₂N) 61 A Continuous, no overload at 40 °C
Max Output Current (Iₘₐₓ) 78 A ≥10 s at start; limited by thermal conditions
Light‑duty Current (I_Ld) 57 A 110% overload for 1 min/5 min at 40 °C
Heavy‑duty Current (I_Hd) 52 A 150% overload for 1 min/5 min at 40 °C
Output Voltage 3‑phase 0–supply voltage
Output Frequency 0–599 Hz
Nominal Motor Power (P_N) 37 kW (50 HP) No‑overload / constant torque
Light‑duty Power (P_Ld) 37 kW (50 HP)
Heavy‑duty Power (P_Hd) 30 kW (40 HP)
DC Bus Voltage 485–675 V DC ±10%
Control Voltage 24 V DC external

Mechanical & Environmental

Parameter Value
Frame Size D
Enclosure IP20 (UL open type)
Dimensions (H×W×D) 483 × 240 × 274 mm (19 × 9.4 × 10.8 in)
Weight ~14 kg (30.9 lb)
Cooling Forced air
Ambient Temp −10 °C to +40 °C (derate above 35 °C)
Altitude Up to 1000 m (derate above)
Humidity 5–95% RH, non‑condensing

Key Features

  • Control: Direct Torque Control (DTC) or scalar; supports induction, PM, SynRM motors
  • Safety: Safe Torque Off (STO) SIL 3 / PL e (EN ISO 13849‑1)
  • Braking: Built‑in brake chopper; external resistor JBR‑06 (13 Ω, 132 kJ, 790 W)
  • Communications: Embedded Modbus; optional fieldbus (PROFINET, EtherNet/IP, Modbus TCP, PROFIBUS, CANopen, etc.)
  • I/O: 6 DI, 2 DI/O, 3 RO, 2 AI, 2 AO; expandable via FIO modules
  • Programming: Embedded PLC (SPC function blocks)

Protection Functions

  • Overcurrent, short‑circuit, earth fault
  • DC over/undervoltage
  • Motor thermal, stall, phase loss
  • External fault, power limits