| Basic Information |
|
| Model |
ACS850-04-430A-5 |
| Product Series |
ACS850 Machinery Drive (Single Drive Module) |
| Frame Size |
G |
| Protection Class |
IP00 |
| Product Code |
3AUA0000056414 |
| Net Weight |
205 kg |
| Dimensions (W×H×D) |
568 mm × 1564 mm × 562 mm |
| Assembly Location |
Finland |
| Electrical Ratings (Input) |
|
| Input Voltage |
3‑phase 380–480 V AC, ±10% |
| Input Frequency |
48–63 Hz |
| Nominal Input Current |
430 A |
| Electrical Ratings (Output) |
|
| Output Voltage |
0–Input Voltage (3‑phase) |
| Output Frequency |
0–300 Hz |
| Nominal Output Current (Iₙ) |
430 A |
| Maximum Output Current (Iₘₐₓ) |
588 A (10 s, 1/10 min duty cycle) |
| Continuous Overload |
110% × Iₙ (1 min, 1/10 min duty cycle) |
| Peak Overload |
150% × Iₙ (10 s, 1/10 min duty cycle) |
| Power Ratings |
|
| Typical Motor Power (400 V) |
200 kW (250 HP) |
| Maximum Motor Power |
Up to 250 kW (335 HP) (application‑dependent) |
| Apparent Power (Sₙ) |
~297 kVA (at 400 V, 430 A) |
| Control & Performance |
|
| Motor Control Method |
Direct Torque Control (DTC) |
| Supported Motor Types |
Asynchronous induction motors, permanent magnet synchronous motors, synchronous reluctance motors |
| Speed Control Accuracy |
±0.01% of rated speed (with encoder); ±0.5% (without encoder) |
| Torque Response Time |
<5 ms |
| Standard Safety Function |
Safe Torque Off (STO) (EN ISO 13849‑1, PL e, Cat. 3) |
| Environmental & Cooling |
|
| Ambient Temperature |
-10°C to +40°C (derating above 40°C) |
| Altitude |
Up to 1000 m (derating above 1000 m) |
| Cooling Method |
Forced air cooling |
| Humidity |
5–95% RH (non‑condensing) |
| Communication & Interfaces |
|
| Standard Fieldbus |
PROFIBUS DP, CANopen, Modbus RTU |
| Optional Fieldbus |
Ethernet/IP, PROFINET, EtherCAT |
| Control I/O |
8 digital inputs, 4 digital outputs, 2 analog inputs, 2 analog outputs |
| Control Panel |
ACS‑CP‑U (standard) |