ACS880-01-061A-3 wall-mounted single drive, IEC: Pn 30 kW, 61 A, 400 V

Part Number: ACS880-01-061A-3
Manufacturer Brands: ABB
Place of Originr: Made in Finland
Net Weight: 18.6 kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
frequency converters, designed for 400V – class 3 – phase AC motor control in industrial scenarios. Below is its detailed technical parameter sheet:

1. Core Electrical Parameters

Parameter Specification
Rated Input Voltage 3 – phase, 380-415 V AC, 50/60 Hz; Allowable voltage range: – 15% / +10% of rated voltage
Rated Input Current 61 A (at 400 V AC, 50/60 Hz)
Rated Output Voltage 3 – phase, 0 to input voltage; Voltage regulation via PWM (Pulse Width Modulation)
Rated Output Current (Normal Use, In) 61 A (continuous operation, 40 °C ambient temperature)
Output Current (Light Overload, ILD) 58 A
Output Current (Heavy Duty, IHD) 45 A
Rated Output Power (Pn) 30 kW (400 V AC, 61 A, cosφ = 0.95)
Output Power (Light Overload, PLD) 30 kW
Output Power (Heavy Duty, PHD) 22 kW
Max Output Power 33 kW (110% of rated power, 1 min per 10 min cycle)
Overcurrent Capacity 150% of rated current for 2 s; 110% of rated current for 60 s
Apparent Power Output 42 kV·A (400 V AC, 61 A)
Rated Input Frequency 50/60 Hz (±5% tolerance)
Power Factor (Input) 0.98 (at rated load)

2. Mechanical & Thermal Parameters

Parameter Specification
Cooling Method Forced air cooling (standard)
Ambient Temperature Operating: – 10 °C to 40 °C (derate 1% / °C above 40 °C up to 50 °C); Storage: – 40 °C to 70 °C
Enclosure Protection IP21 (standard); NEMA Type 1
Frame Size R4
Dimensions (H×W×D) 580 mm × 203 mm × 274 mm (22.83 in × 7.99 in × 10.79 in)
Net Weight 18.6 kg (41.01 lbs)
Noise Level ≤ 62 dB(A) (1 m distance, rated load)
Altitude Max 4000 m (derate 1% rated current per 100 m above 1000 m)
Operating Humidity 5% – 95% (non – condensing)

3. Control & I/O Parameters

Parameter Specification
Control Modes DTC (Direct Torque Control), V/f control, scalar control, sensorless vector control, vector control with encoder feedback
Digital Inputs 6 × 24 V DC (configurable)
Digital Outputs 2 × relay outputs (250 V AC / 30 V DC, 5 A)
Analog Inputs 2 × (0-20 mA / 4-20 mA / 0-10 V) (configurable)
Analog Outputs 2 × (0-20 mA / 4-20 mA) (configurable)
Communication Interfaces Standard: Modbus RTU, PROFIBUS DP; Optional: PROFINET IO, EtherNet/IP, DeviceNet
Standby Loss 28 W

4. Efficiency & Loss Data

Parameter Specification
Efficiency Level IE2
Absolute Loss (25% load) 232 W; Efficiency: 95.2%
Absolute Loss (50% load) 334 W; Efficiency: 96.4%
Absolute Loss (100% load) 643 W; Efficiency: 96.5%
Total Loss (Rated Load) 643 W

5. Protection & Compliance

Parameter Specification
Protection Functions Overvoltage, undervoltage, overcurrent, overload, overheating, short – circuit, earth fault, motor phase – loss protection; STO (Safe Torque Off) as standard
Compliance Standards IEC 61800-5-1, IEC 61800-3, CE, UL, CSA