The ACS880-04-505A-3+D150+N5050 is a 3-phase AC single-drive module of ABB ACS880 series, frame size R10 with IP20 enclosure for cabinet assembly. +D150 is an integrated brake chopper for reliable motor braking, and +N5050 is a crane control program tailored for hoisting applications with specialized logic and safety integration. Below is its detailed technical parameter sheet:
1. Core Electrical Parameters
| Parameter | Specification |
|---|---|
| Rated Input Voltage (3-phase) | 380-415 V AC (400 V nominal); Allowable range: 380-500 V AC |
| Rated Input Frequency | 50/60 Hz (48-63 Hz allowable) |
| Rated Output Current (In, 40 °C ambient) | 505 A (continuous, 3-phase) |
| Light Overload Current (ILd) | 485 A (10% overload, 1 min/5 min cycle) |
| Heavy Duty Current (IHD) | 361 A (50% overload, 1 min/5 min cycle) |
| Max Output Current (Imax) | 560 A (10 s, starting); 560 A (110% of In, 60 s); 758 A (150% of In, 2 s) |
| Rated Output Power (Pn, 400 V, cosφ=0.95) | 250 kW |
| Light Overload Power (PLd) | 250 kW |
| Heavy Duty Power (PHD) | 200 kW |
| Max Output Power | 275 kW (110% of Pn, 1 min/10 min cycle) |
| Rated Output Voltage | 3-phase, 0 to 480 V AC (PWM regulation) |
| Apparent Output Power | 350 kV·A (400 V, 505 A) |
| Output Power Factor | 0.95 (at rated load) |
| Rated Load Power Loss | 4521 W |
| Brake Chopper (D150 Option) | Rated braking power 200 kW; Max braking current 361 A; Duty cycle: 150% In for 2 s |
2. Mechanical & Thermal Parameters
| Parameter | Specification |
|---|---|
| Cooling Method | Forced air cooling (standard) |
| Ambient Temperature | Operating: -10 °C to 40 °C (derate 1%/°C above 40 °C up to 50 °C); Storage: -40 °C to 70 °C |
| Enclosure Protection | IP20 (UL Open Type, cabinet installation) |
| Frame Size | R10 |
| Dimensions (H×W×D) | 1541 mm × 350 mm × 505 mm (28.58 in × 9.88 in × 14.06 in) |
| Net Weight | 161 kg (354.9 lbs) |
| Noise Level | ≤ 72 dB(A) (1 m distance, rated load) |
| Max Altitude | 4000 m (derate 1% In per 100 m above 1000 m) |
| Operating Humidity | 5% – 95% (non-condensing) |
3. Control, I/O & Optional Features
| Parameter | Specification |
|---|---|
| Control Modes | DTC, V/f, sensorless vector, vector with encoder feedback |
| Digital Inputs | 6 × 24 V DC (configurable) |
| Digital Outputs | 2 × relay (250 V AC/30 V DC, 5 A) |
| Analog Inputs | 2 × (0-20 mA/4-20 mA/0-10 V, configurable) |
| Analog Outputs | 2 × (0-20 mA/4-20 mA, configurable) |
| Communication Interfaces | Standard: Modbus RTU; Optional: PROFINET IO, EtherNet/IP, DeviceNet, PROFIBUS DP |
| Standby Loss | 392 W |
| D150 Brake Chopper | Integrated, works with external resistors; Overvoltage/overcurrent protection |
| N5050 Crane Control | Hoisting logic, load monitoring, speed/torque control, STO (SIL 3, PL e) integration |
4. Efficiency & Loss Data
| Parameter | Specification |
|---|---|
| Efficiency Level | IE2 |
| 25% Load, 0 Hz | Loss: 1802 W; Efficiency: 91.2% |
| 50% Load, 0 Hz | Loss: 2543 W; Efficiency: 93.5% |
| 100% Load, 0 Hz | Loss: 4521 W; Efficiency: 94.2% |
| 100% Load, 50 Hz | Loss: 5260 W; Efficiency: 96.7% |
5. Protection & Compliance
| Parameter | Specification |
|---|---|
| Protection Functions | Overvoltage, undervoltage, overcurrent, overload, overheating, short-circuit, earth fault, motor phase-loss; STO (SIL 3, PL e) standard; Brake chopper OV/OC protection (D150) |
| Compliance | IEC 61800-5-1, IEC 61800-3, CE, UL, CSA |