This datasheet describes the ABB ACS880-04-590A-7, a 3-phase, open – chassis drive module with 590A output current and 560kW (750HP) rating at 690V, equipped with Direct Torque Control (DTC) for precise speed and torque control, ideal for industrial machinery like mixers, centrifuges, conveyors, and cranes requiring reliable performance.
General Information
| Item | Specification |
|---|---|
| Model Number | ACS880-04-590A-7 |
| Product Family | ACS880 Series |
| Ordering Code | 3AUA0000232410 (base) |
| Frame Size | R11 |
| Mounting Type | Floor – standing, open chassis (IP20) |
| Enclosure Protection | IP20 (UL Open Type) |
| Control Panel | Assistant Bluetooth (optional) |
| Standard Feature | Built – in choke for harmonic filtering |
Electrical Ratings
| Parameter | Value |
|---|---|
| Input Voltage | 3 – phase, 525-690V AC (690V nominal), 50/60Hz |
| Output Voltage | 3 – phase, 0 – Input Voltage, 0-500Hz (adjustable based on control mode) |
| Output Current (Normal Duty) | 590A (560kW/750HP at 690V) |
| Output Current (Heavy Duty) | 505A (500kW/670HP at 690V) |
| Output Current (Light Overload) | 571A (560kW/750HP at 690V) |
| Overload Capacity | 150% for 1 minute, 110% for continuous (typical) |
| Efficiency | >98% (at rated load) |
| Power Factor | >0.98 (at rated load) |
| Power Dissipation | 9862W |
Mechanical Dimensions & Weight
| Dimension | Value |
|---|---|
| Height | 1730 mm (68.11 in) |
| Width | 620 mm (24.41 in) |
| Depth | 478 mm (18.82 in) |
| Net Weight | 380 kg (838 lbs) |
Communication & Control
| Feature | Specification |
|---|---|
| Control Method | Direct Torque Control (DTC) |
| Standard Protocols | Modbus RTU (built – in); PROFIBUS DP, Ethernet/IP (optional) |
| I/O Configuration | 6 digital inputs, 3 relay outputs, 2 analog inputs, 2 analog outputs (configurable) |
Protection & Safety
| Protection Feature | Description |
|---|---|
| Overcurrent Protection | Trips when output current exceeds the set threshold |
| Overvoltage Protection | Activates when DC bus voltage is overly high |
| Undervoltage Protection | Triggers when input voltage is below the minimum limit |
| Overtemperature Protection | Shuts down the drive if heatsink temperature is too high |
| Short Circuit Protection | Protects against output short circuits |
| STO Function | Safe Torque Off (SIL3 as per IEC61511, SILCL3 as per IEC62061, PLe ISO13849 – 1) |
Environmental Conditions
| Condition | Range |
|---|---|
| Operating Temperature | -15°C to +40°C (5°F to 104°F); derate 1% per 10°C above 40°C |
| Storage Temperature | -40°C to +70°C (-40°F to 158°F) |
| Relative Humidity | 5% to 95% (non – condensing) |
| Altitude | Up to 1000m (3300ft) without derating; derate 1% per 100m above 1000m |
| Vibration | 0.5g (5Hz to 150Hz) |