Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6SY7010-0AB02 Siemens Thyristor Module

6SY7010-0AB02
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany

Inquire this item

6SY7010-0AB02

6SY7010-0AB02 Technical Parameters

Basic Information

  • Model: 6SY7010-0AB02
  • Type: Layer A Thyristor Block, built-in RC snubber circuit, for infeed / regenerative unit
  • Brand / Origin: Siemens, Made in Germany
  • Applicable Equipment: SIMOVERT MV, 6SE70 / 6RA70 series high-power inverter and DC drive units (400V class)
  • Status: EOL (End of Life), original spare parts available for ordering

Electrical Rated Parameters (Official & Measured, 25℃, Water Cooling)

Parameter Value Unit Remarks
Rated 3-phase AC Input Voltage 380~460 V 50/60Hz
Rated On-state RMS Current 1180 A Continuous, water cooling
Repetitive Peak Off-state Voltage 1600 V Repetitive, 50Hz
Repetitive Peak Reverse Voltage 1600 V Repetitive, 50Hz
Non-repetitive Surge Current 1420 A (Peak) 50Hz half-wave, ℃
Gate Trigger Current ≤2.0 A DC
Gate Trigger Voltage ≤3.6 V DC
Holding Current 1200~1400 mA Typical: 1300mA
On-state Voltage Drop ≤1.9 V At , typical: 1.8V
Snubber Circuit Built-in RC Original integrated dv/dt suppression

Environmental & Mechanical Parameters (Official)

  • Operating Junction Temperature : -40 ~ +125 ℃ (Long-term)
  • Storage Temperature: -55 ~ +150 ℃
  • Cooling Method: Water cooling (standard, flow ≥8L/min); Forced air cooling (optional, 20% derating)
  • Weight: 26.5 kg (±0.5kg)
  • Dimensions (W×H×D): 730 × 380 × 450 mm
  • Protection Class: IP20 (Module body)
  • Insulation Withstand Voltage: AC 2500V / 1min (Module to heat sink)

Key Difference vs 6SY7010-0AB01

  • 6SY7010-0AB01: , Surge 1230A
  • 6SY7010-0AB02: , Surge 1420A

    Same voltage and package, current capacity increased by 15%.

Compatible Replacement Models

  • 6SY7010-0AB02 → 6SY7010-0AB15 (500~575V, 1180A)
  • 6SY7010-0AB02 → 6SY7010-0AB31 (660~690V, 1285A)

Application Limitations

  1. Only applicable for Siemens original rectifier / regenerative units; cannot directly replace non-original modules.
  2. Water cooling requirement: Inlet temperature ≤35℃, pressure 0.3~0.6MPa, flow ≥8L/min.
  3. Junction temperature strictly not to exceed 125℃, otherwise irreversible aging occurs.

Leave a Replay