Core Electrical & Power Parameters
| Parameter | Value | Description |
|---|---|---|
| Input Voltage | 3-phase AC 400V (380–480V range) | Nominal supply voltage for control section |
| Field Output Current | 40A (continuous) | Controllable field rectifier output |
| Field Output Voltage | Up to 300V DC | Max voltage for field winding |
| Power Rating | N/A (control module only, no power unit) | Works with external power section |
| Connection Type | (B6)A(B6)C | Circuit topology for 4-quadrant operation |
| Frequency | 50/60Hz | Compatible with standard grids |
| Control Supply | 230V AC (±15%), 50/60Hz | Auxiliary power for logic & control |
| Control Power Consumption | ~150VA | Typical for microprocessor & I/O circuits |
Z-Option Details (G95+K00+K01+K11)
| Option | Part Number | Function |
|---|---|---|
| G95 | 6SE7090-0XX84-0FF5 | Communication module (PROFIBUS DP) |
| K00 | — | Base terminal configuration |
| K01 | 6SE7090-0XX84-0KA0 | Slot D adapter module |
| K11 | 6SE7090-0XX84-4HA0 | Slot E adapter module |
Physical & Environmental
| Parameter | Value | Notes |
|---|---|---|
| Dimensions (W×H×D) | 50.5×25.0×27.0 cm | Chassis mount form factor |
| Weight | 18.1 kg | Shipping weight ~19.1 kg |
| Operating Temp | 0–40°C | Derate above 40°C |
| Storage Temp | -25–70°C | No condensation |
| Humidity | 5–95% RH (non-condensing) | IP20 protection class |
| Cooling | Forced air (internal fan) | Ensures component reliability |
Control & Interface Features
- 32-bit Microprocessor:Enables precise current/voltage/speed control with fast response.
- Closed-Loop Control:Current, speed, and position loops with auto-tuning (P/I parameters).
- I/O Interface:
- 8 digital inputs (24V DC, opto-isolated)
- 4 digital outputs (relay, 250V AC/30V DC, 5A)
- 2 analog inputs (±10V, 12-bit resolution)
- 2 analog outputs (±10V, 12-bit)
- Communication:PROFIBUS DP (via G95) for PLC integration; supports USS protocol.
- Protection:Overcurrent, overvoltage, undervoltage, overtemp, field loss, and short-circuit protection.
- Diagnostics:LED indicators, fault codes, and event log for troubleshooting.
Ordering & Compatibility
- Full Part Number:6RA7000-0MV62-0-ZG95+K00+K01+K11
- Replacement:6RA8000-0MV62-0AA0 (SINAMICS DCM equivalent)
- Mounting:19-inch rack or wall-mount (with adapter)
- Certifications:CE, UL, cUL compliant