Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA8025-6DV62-0AA0 SINAMICS DCM DC converter 400V 3AC, 50 A

Part Number: 6RA8025-6DV62-0AA0
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 12,00 Kg
Product Size: 520,00 x 380,00 x 390,00 mm

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
Order No.:6RA8025-6DV62-0AA0

Brand:Siemens

Series:SINAMICS DCM

Type:DC Converter, 4‑quadrant operation (forward/reverse motoring & regenerative braking)

Topology:(B6)A + (B6)C fully controlled 3‑phase bridge

Status:PM300 Active (in production)


1. Armature Input Specifications

Parameter Value
Input type 3‑phase AC
Rated input voltage 400 V AC, +15 % / −20 %
Permissible input voltage 320 … 460 V AC
Rated input current 50 A
Input frequency 45 … 65 Hz
Control electronics supply 2‑phase AC 380 … 480 V, 50/60 Hz
Fan supply Integrated, powered from main input
Cooling system Forced ventilation (AF)

2. Armature Output Specifications

Parameter Value
Rated output voltage 420 V DC
Rated output current 60 A
Rated output power 25.2 kW
Operation mode 4‑quadrant (forward/reverse, motoring/regeneration)
Dynamic overload 110% × 60 s; 150% × 5 s
Steady‑state overload 105% continuous (thermal‑limited)
Rectifier type Thyristor‑based, fully controlled

3. Built-in Field Circuit Specifications

Parameter Value
Field rectifier model D420/60 MREQ‑GEG6V62
Field input supply 2‑phase AC 380 … 480 V
Max. field output voltage Up to 325 V DC
Max. field output current 10 A
Field control Fully controllable, closed‑loop adjustable excitation
Function For separately excited DC motor field winding

4. Power, Loss & Efficiency

Parameter Value
Rated output power 25.2 kW
Typical power loss at rated load ~0.25 kW
Typical efficiency ≥99.0 % at rated load

5. Mechanical & Environmental Data

Parameter Value
Dimensions (W×D×H) Approx. 250 × 280 × 400 mm
Net weight Approx. 12.0 kg
Protection class IP20
Ambient operating temperature 0 … 40 °C (derate above 40 °C)
Storage/transport temperature −40 … +70 °C
Installation altitude Up to 1000 m above sea level
Installation orientation Vertical, wall‑mounted

6. Protection Functions

  • Overcurrent, overvoltage, undervoltage protection
  • Overtemperature, phase failure, short‑circuit protection
  • Field loss, overspeed, motor overtemperature protection
  • Electronic thermal motor protection
  • Earth‑fault detection & protection

7. Standards & Certifications

Compliant with EN 50178, EN 60146‑1‑1, EN 61800‑1, EN 61800‑3, EN 61800‑5‑1, IEC 62103, UL/CSA recognized

8. Key Features & Applications

  • 4‑quadrant operation with full regenerative energy feedback
  • Integrated field power unit (no external field controller required)
  • 32‑bit microprocessor, high‑precision closed‑loop speed & current control
  • Support for encoder/tachometer feedback, high dynamic response
  • Wide speed regulation range, strong low‑speed torque
  • Suitable for medium‑power industrial applications: conveyors, winders, small extruders, mixers, test stands, pumps, fans, and general medium‑power DC motor drive systems