Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6SE7014-0TP60 SIMOVERT MASTERDRIVES

Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
Product Family: SIMOVERT MASTERDRIVES VC (Vector Control) – Compact Plus Inverter (Air-Cooled)

Part Number: 6SE7014-0TP60

Status: Discontinued (PM490: Final Year of Support)


1. Power Ratings (Output)

Parameter Value Unit Notes
Rated Power (PN) 1.5 kW For 3-phase induction motor, 400V class
Rated Output Current (IN) 4.0 A Continuous output current
Base Load Current (IG) 3.6 A 100% continuous duty
Peak/Short-Term Current (Imax) 6.4 A 160% IN for 60 seconds
DC Link Rated Current (IZKn) 4.8 A DC bus current rating
Output Frequency Range 0–650 Hz V/F & Vector control modes
Switching Frequency 2.5 kHz Default; adjustable 2–16 kHz
Efficiency (Typical) ≥96 % At rated load, 400V supply

2. Voltage Ratings (Input/DC Link/Output)

Parameter Value Unit Notes
AC Supply Voltage (3-phase) 380–480 V ±15% tolerance; 50/60 Hz
DC Link Voltage (UDC) 510–650 V Rectified DC bus; 380V AC → ~540V DC
Rated Output Voltage 0–400 V 3-phase, adjustable 0–100% of supply
Voltage Ripple (DC Link) ≤5 % At rated load
Overvoltage Protection 750 V DC link overvoltage trip threshold
Undervoltage Protection 380 V DC link undervoltage trip threshold

3. Mechanical & Environmental

Parameter Value Unit Notes
Dimensions (W × H × D) 67.5 × 360 × 260 mm Ultra-slim 67.5mm width (Compact Plus)
Weight 3.0 kg
Protection Class IP20 Touch-safe; dust-protected
Ambient Temperature 0–40 °C Continuous operation
Storage Temperature -20–60 °C
Relative Humidity ≤95 % Non-condensing
Cooling Method Forced Air Internal fan; 0.002 m³/s airflow
Noise Level (50 Hz) ≤18 dB(A) At 1m distance
Vibration Resistance 0.1g 10–1000 Hz

4. Control & Performance

Parameter Value Unit Notes
Control Modes V/F, Sensorless Vector (VC), Closed-Loop Vector With encoder feedback option
Speed Regulation (Sensorless) ±0.5 % At rated speed
Speed Regulation (Closed-Loop) ±0.01 % With encoder
Torque Response Time <10 ms Dynamic torque control
Motor Identification Auto-Tuning For induction motors
Overload Capacity 160% IN for 60s; 120% IN continuous
Dynamic Braking Built-in DC injection braking; external resistor optional
Communication Interfaces RS485 (USS), Profibus-DP (option), CANopen (option)
Digital I/O 6 inputs, 4 outputs 24V DC
Analog I/O 2 inputs (0–10V/4–20mA), 1 output (0–10V/4–20mA)

5. Electrical & Protection

Parameter Value Unit Notes
Power Supply (Control) 24V DC A 1.3 A max; external supply required
Power Terminals (Motor) 3 × 10 mm² Fine-stranded; E-CU terminals
DC Link Terminals 4 mm²
Protection Features Overcurrent, overvoltage, undervoltage, overtemperature, ground fault, motor overload
Thermal Protection PTC/KTY84 input Motor temperature monitoring
Short-Circuit Protection IGBT-based Instant trip

Leave a Replay