Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6SL3120-1TE31-3AA3 SINAMICS S120 3AC 400V, 132A

Part Number: 6SL3120-1TE31-3AA3
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 20,7 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.
This is the complete English technical specification sheet for Siemens 6SL3120-1TE31-3AA3 SINAMICS S120 single motor module, covering core electrical ratings, performance, protection, mechanical/environmental data, and functional details, based on Siemens official documentation and certified industrial catalogs.

1. Core Electrical Specifications

Parameter Value Unit Notes
Product Model 6SL3120-1TE31-3AA3 SINAMICS S120 single motor module, booksize, internal air cooling, with DRIVE‑CLiQ cable
DC Link Input Voltage 510–720 (rated: 600) V DC DC bus voltage range; compatible with S120 DC link system
AC Output (3‑phase) 0–400 (max: 0.717×DC link) V AC 3‑phase output, matches DC link voltage scaling
Rated Output Current (0–40°C) 132 A Continuous operation at rated DC link voltage
Rated Output Power 75 kW At 400 V AC output, 132 A rated current
Peak Output Current 264 (200% of rated) A For 2 s, with 60‑second cool‑down interval
DC Link Capacitance 2820 µF Stable DC bus voltage support
Pulse Frequency 4 (max: 16 with derating) kHz Default 4 kHz; adjustable via control unit
Electronics Power Input 24 (20.4–28.8 tolerance) V DC Power for control electronics
Total Power Dissipation 1270.4 W Typical power loss under rated load

2. Overload Capabilities

Overload Condition Current Duration Ambient Temperature
Peak Overload 264 (200% of rated) 2 s 0–40°C
Continuous Overload 145.2 (110% of rated) 60 s 0–40°C
Continuous Operation 132 (100% of rated) Continuous 0–40°C; derate above 40°C

3. Performance & Protection Specifications

Parameter Value Unit Notes
Control Modes Vector (sensorless/encoder), V/F Supports precise motor control via S120 control units
Current Control Accuracy ±0.5% of rated current Closed‑loop current regulation for dynamic performance
Overcurrent Protection 200% of rated current Instantaneous trip to prevent device damage
Overvoltage Protection 720 V DC DC bus overvoltage clamping
Undervoltage Protection 510 V DC Shuts down to prevent IGBT damage
Overheating Protection 85 °C Heatsink temperature threshold; fan speed control + alarm/trip
Short‑circuit Protection Internal fast‑acting fuses Coordinated with power section design
Safety Functions STO (Safe Torque Off), SS1, SS2 Extended safety integrated functions compliant with EN 61800‑5‑2
EMC Compliance EN 61800‑3, Category C2 Suitable for industrial environments

4. Mechanical & Environmental Specifications

Parameter Value Unit Notes
Cooling Method Internal air cooling Integrated fan with speed monitoring
Cooling Airflow Requirement 520 m³/h Airflow for internal heat dissipation
Net Weight 18 kg Base unit without packaging
Dimensions (H×W×D) 482×175×280 mm Booksize frame, compact for cabinet installation
Ambient Temperature 0–40 °C Operating; derate 1% per 100 m above 1000 m altitude
Storage/Transport Temperature −25 to +70 °C
Installation Altitude ≤1000 m Derate 1% per 100 m above 1000 m
Relative Humidity 5–95% % Non‑condensing
Vibration Resistance 0.5 g 10–150 Hz, IEC 60068‑2‑6
Shock Resistance 15 g 11 ms, IEC 60068‑2‑27
IP Rating IP20 Enclosure protection class for cabinet mounting
Sound Pressure Level (1m) 68 dB Under standard operating conditions

5. Key Functional & Compliance Details

  • DRIVE‑CLiQ Interface: Integrated DRIVE‑CLiQ cable for seamless connection to S120 control units (CU320‑2) and adjacent modules, enabling fast data exchange and configuration.
  • Safety Integration: Supports Safe Torque Off (STO), Safe Stop 1 (SS1), and Safe Stop 2 (SS2) per EN 61800‑5‑2, enhancing operator and machine safety.
  • Cooling System: Internal fan with speed monitoring ensures stable thermal performance; airflow of 520 m³/h required for optimal cooling.
  • Typical Applications: Ideal for precision motor control in machine tools, conveyors, hoists, and automated production lines requiring dynamic speed/torque regulation.

6. Supplementary Notes

  1. Overload Limitation: Peak overload (200% of rated current) is limited to 2 seconds to prevent thermal damage; ensure cool‑down intervals are observed.
  2. Pulse Frequency: Higher pulse frequencies (up to 16 kHz) require current derating; refer to Siemens S120 Pulse Frequency Derating Guide for details.
  3. Documentation: Refer to Siemens SINAMICS S120 Single Motor Module Manual (Document No. 6SL3120‑1TE31‑3AA3) for complete parameterization and troubleshooting.