1. Core Electrical Ratings
| Parameter | Value | Notes |
|---|---|---|
| DC Link Input Voltage | DC 510 … 720 V (nominal 600 V DC) | Busbar-fed from S120 Line Module |
| 3-Phase AC Output Voltage | Up to 0.717 × DC-link voltage (typical 400 V 3AC) | Line-commutated from DC link |
| Rated Output Current (IN) | 200.0 A | Continuous base load |
| Base Load Current (IH) | 141.0 A | S1 continuous duty |
| S6 Duty (40% ED) Current (IS6) | 230.0 A | Intermittent overload |
| Peak Current (Imax) | 282.0 A | Short-time peak (1.41× IN) |
| DC Link Current (Id) | 200.0 A | For external DC connection sizing |
| Rated Output Power (IN) | 107.0 kW | Typical 400V 3AC induction motor rating |
| Rated Output Power (IH) | 76.0 kW | S1 continuous rating |
| Electronics Power Supply | 24 V DC (-15% / +20%) | Max current demand: 1.50 A |
| Rated Pulse Frequency | 4.00 kHz | Standard; up to 16 kHz with derating |
| Output Frequency (Servo Control) | 0 … 650 Hz (licensed) / 0 … 550 Hz (std) | Max 1300 Hz (62.5µs current cycle, 8kHz pulse, 60% current derate) |
| Output Frequency (V/f Control) | 0 … 600 Hz (licensed) / 0 … 550 Hz (std) | Current derate applies at high frequencies |
| Output Frequency (Vector Control) | 0 … 300 Hz (std) | Current derate applies at high frequencies |
| DC Link Capacitance | 3995 µF | Internal DC bus capacitance |
| 24V Busbars Current Rating | 20 A | Use terminal adapter for >20 A series connection |
| DC Link Busbars Current Rating | 200 A | Internal DC busbar capacity |
2. Mechanical & Environmental Data
| Parameter | Value | Notes |
|---|---|---|
| Dimensions (W×H×D) | 300.0 × 380.0 × 270.0 mm (11.81 × 14.96 × 10.63 in) | Booksize, single-channel high-power design |
| Net Weight | 21.0 kg (46.30 lb) | Excl. cables & accessories |
| Degree of Protection | IP20 / UL open type | For indoor, protected installation |
| Cooling | Internal air cooling (integrated fan) | Intensified air cooling for high load |
| Cooling Air Requirement | 0.144 m³/s | Nominal airflow at rated load |
| Ambient Temperature (Operation) | 0 … 40 °C (32 … 104 °F) | No derating up to 1000 m altitude |
| Installation Altitude (No Derating) | ≤ 1000 m (3281 ft) | Derate current above 1000 m |
| Sound Pressure Level (1m) | 73.0 dB | Typical at rated load |
| Power Loss (Typ./Max.) | 2.03 kW / 2.09 kW | Includes 24V electronics supply losses |
3. Connections & Cabling
| Connection | Details |
|---|---|
| Motor Connector (X1) | M8 bolt terminal; Conductor cross-section: 3 … 120 mm² (14 … -3 AWG) |
| Max Motor Cable Length | Shielded: 100 m (328 ft); Unshielded: 150 m (492 ft) |
| PE Connection | M8 screw terminal |
| DRIVE-CLiQ Interfaces | 3 ports (for CU320/CU320-2 control units & peripherals) |
| DC Link Interfaces | 2 integrated DC busbar terminals (for parallel/series connection) |
| Additional Ports | Motor temperature sensor, Safe Torque Off (STO) input, motor brake controller |