1. Core Electrical Ratings
| Parameter | Value | Notes |
|---|---|---|
| DC Link Input Voltage | DC 510 … 720 V (nominal 600 V DC) | Busbar-fed from S120 Line Module |
| 3-Phase AC Output Voltage | 400 V 3AC | Line-commutated from DC link |
| Rated Output Current (IN) | 2 × 9.0 A | Continuous base load (per channel) |
| Base Load Current (IH) | 2 × 7.6 A | S1 continuous duty (per channel) |
| S6 Duty (40% ED) Current (IS6) | 2 × 12.0 A | Intermittent overload (per channel) |
| Peak Current (Imax) | 2 × 27.0 A | Short-time peak (3× IN per channel) |
| DC Link Current (Id) | 21.5 A | For external DC connection sizing |
| Rated Output Power (IN) | 2 × 4.8 kW | Typical 400V 3AC induction motor rating |
| Rated Output Power (IH) | 2 × 4.1 kW | S1 continuous rating |
| Electronics Power Supply | 24 V DC (-15% / +20%) | Max current demand: 0.90 A |
| Rated Pulse Frequency | 4.00 kHz | Standard; up to 8 kHz with high-frequency license |
| Output Frequency (Servo Control) | 650 Hz (licensed) / 550 Hz (std) | Max 1300 Hz (62.5µs current cycle, 8kHz pulse, 60% current derate) |
| Output Frequency (V/f Control) | 600 Hz (licensed) / 550 Hz (std) | Current derate applies at high frequencies |
| Output Frequency (Vector Control) | 300 Hz (std) | Current derate applies at high frequencies |
| DC Link Capacitance | 705 µF | Internal DC bus capacitance |
| 24V Busbars Current Rating | 20 A | Use terminal adapter for >20 A series connection |
| DC Link Busbars Current Rating | 200 A | Internal DC busbar capacity |
2. Mechanical & Environmental Data
| Parameter | Value | Notes |
|---|---|---|
| Dimensions (W×H×D) | 100.0 × 380.0 × 270.0 mm (3.94 × 14.96 × 10.63 in) | Booksize D-Type, dual-channel compact design |
| Net Weight | 4.7 kg (10.36 lb) | Excl. cables & accessories |
| Degree of Protection | IP20 / UL open type | For indoor, protected installation |
| Cooling | Internal air cooling (integrated fan) | Intensified air cooling for high load |
| Cooling Air Requirement | 0.012 m³/s | Nominal airflow at rated load |
| Ambient Temperature (Operation) | 0 … 40 °C (32 … 104 °F) | No derating up to 1000 m altitude |
| Installation Altitude (No Derating) | ≤ 1000 m (3281 ft) | Derate current above 1000 m |
| Sound Pressure Level (1m) | 58.0 dB | Typical at rated load |
| Power Loss (Typ./Max.) | 0.14 kW / 0.18 kW | Includes 24V electronics supply losses |
3. Connections & Cabling
| Connection | Details |
|---|---|
| Motor Connectors (X1, X2) | Conductor cross-section: 1.5 … 4 mm² (16 … 12 AWG) |
| Max Motor Cable Length | Shielded: 70 m (230 ft); Unshielded: 100 m (328 ft) |
| PE Connection | M5 screw terminal |
| DRIVE-CLiQ Interfaces | 3 ports (for CU320/CU320-2 control units & peripherals) |
| DC Link Interfaces | 2 integrated DC busbar terminals (for parallel/series connection) |
| Additional Ports | Motor temperature sensor, Safe Torque Off (STO) input, motor brake controller (per channel) |
4. Safety & Compliance
- Safety Integrated: STO (Safe Torque Off), extended safety functions (SS1, SLS, etc.) supported
- Safety Ratings: SIL 2 (IEC 61508), PL d (EN ISO 13849-1), Category 3 (EN ISO 13849-1)
- Certifications: CE, cULus, UPC 804766208270
- Standards Compliance: IEC 61800, EN 61800, UL 508C, CSA C22.2 No. 14