6SL3320-1TE32-1AA3 Detailed English Specifications (Siemens SINAMICS S120 Single Motor Module)
This is a chassis – mounted, air – cooled single motor module for the Siemens SINAMICS S120 converter system, which is applicable to 3 – phase industrial drive scenarios, and supports extended safety – integrated functions, with a rated output current of 210A and a rated power of 150kW (based on IN at 400V 3AC). The detailed parameter tables are as follows:
Basic Identification
| Item | Details |
|---|---|
| Part Number | 6SL3320-1TE32-1AA3 |
| Product Type | SINAMICS S120 Single Motor Module |
| Manufacturer | Siemens |
| Application | Industrial 3 – phase AC drives, compatible with servo/V/f/vector control |
| Mounting Type | Chassis – mounted |
| Cooling Method | Internal forced air cooling |
| Protection Class | IP20 |
| Net Weight | Approx. 95 kg |
| RoHS Compliance | Yes |
| Communication Interface | DRIVE – CLiQ (incl. cable) |
| Safety Functions | Extended Safety Integrated (e.g., STO, SS1, SS2) |
Electrical Specifications (Core)
| Parameter | Value | Unit | Remarks |
|---|---|---|---|
| DC Link Input Voltage | 510-750 (nominal 600) | V DC | Working voltage range |
| DC Link Rated Current (IN DC) | 252 (Basic/Smart Line Module); 227 (Active Line Module) | A | Rated current matching different line modules |
| DC Link Base – load Current (IL DC) | 245 (Basic/Smart Line Module); 221 (Active Line Module) | A | Continuous base – load current |
| DC Link Base – load Current (IH DC) | 224 (Basic/Smart Line Module); 202 (Active Line Module) | A | High – temperature base – load current |
| Rated Output Current (IN) | 210 | A | 3 – phase AC output, 400V, 50/60Hz |
| Base – load Output Current (IL) | 205 | A | Continuous base – load output current |
| High – temp Base – load Output Current (IH) | 178 | A | Output current under high – temperature base – load |
| S6 Duty (40%) Current (IS6) | 230 | A | Short – term overload (40% duty cycle) |
| Rated Output Power (IN – based) | 150 | kW | At 400V 3AC, 50Hz |
| Rated Output Power (IH – based) | 90 | kW | At 400V 3AC, 50Hz |
| Output Voltage | 0.0-0.75 × DC link voltage (max. 400) | V AC (3 – phase) | Proportional to DC link input |
| Output Frequency | 0-550 | Hz | For servo/V/f/vector control |
| Rated Switching Frequency | 2.0 | kHz | Fixed max. 2.0 kHz |
| DC Link Capacitance | 4,200 | µF | Filtering and energy storage |
| Control Voltage | 24 (-15%/+20%) | V DC | Auxiliary power supply, current consumption 0.63A at 400V AC |
| Insulation Voltage | 1080 | V AC (1 min) | Dielectric strength test value |
Thermal & Environmental
| Parameter | Value | Unit | Derating/Notes |
|---|---|---|---|
| Operating Temperature (No Derating) | 0-40 | °C | Continuous operation |
| Operating Temperature (Derating) | 40-60 | °C | Linear derating applies |
| Storage Temperature | -25-70 | °C | No condensation allowed |
| Relative Humidity | 5-95 | % | Non – condensing, no corrosive gases |
| Altitude (No Derating) | ≤1000 | m | Standard condition |
| Altitude (Derating) | >1000 | m | 1% derating per 100m above 1000m |
| Vibration Resistance | 5-150Hz, 0.5 | g | Compliant with IEC 60068-2-6 |
| Shock Resistance | 10g, 11 | ms | Compliant with IEC 60068-2-27 |
| Sound Pressure Level (1m) | 71 | dB (50/60Hz) | Typical operation noise |
Power Loss & Protection
| Parameter | Value | Unit | Remarks |
|---|---|---|---|
| Max. Power Loss | Approx. 2.5 | kW | At 400V, 50Hz, full load |
| Short – Circuit Protection | Internal fast – acting fuses | — | Compliant with IEC 60947-4-1 |
| Overvoltage Protection | DC link varistor + active clamping | — | Triggers at ~780V DC |
| Overcurrent Protection | Electronic current limiting (up to 307A peak) | A | Protects power devices |