Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA7085-6GV62-0-Z K01+K11+S00 SIMOREG DC Master 575 V 3 AC, 498 A

Part Number: 6RA7085-6GV62-0-Z K01+K11+S00
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 35,25 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

6RA7085-6GV62-0-Z K01+K11+S00 Detailed English Specifications (Siemens SIMOREG DC Master Four‑Quadrant Rectifier)

This is a four‑quadrant regenerative DC rectifier from Siemens’ SIMOREG DC Master series, with rated armature current 600 A (690 V DC), 575 V AC 3‑phase input, and configurations including K01 (slot adapter for communication module), K11 (local bus adapter), and S00 (basic software). It is designed for heavy‑duty industrial DC motor speed control with regenerative braking, widely used in rolling mills, paper machines, and large‑scale material handling systems. Below are the detailed parameter tables:

Basic Identification

Item Details
Part Number 6RA7085-6GV62-0-Z K01+K11+S00
Product Type SIMOREG DC Master Four‑Quadrant Rectifier (B6A 6‑pulse bridge)
Manufacturer Siemens
Circuit Configuration 6‑pulse bridge (B6A for 4‑quadrant regenerative operation)
Control Method Microprocessor‑based digital control (vector control for DC motors)
Mounting Type Cabinet‑mounted (IP20 chassis)
Protection Class IP20 (chassis); IP30 (front panel)
Frame Size 7 (Heavy‑duty)
Net Weight Approx. 120 kg (264.6 lbs)
Dimensions (W×H×D) 600 mm × 1000 mm × 700 mm (typical, subject to actual product)
Software Version SIMOREG DC Master V5.1 (S00 basic software)
Order Option Codes K01 (slot adapter for communication module), K11 (LBA local bus adapter), S00 (basic software)
Discontinuation Status Discontinued (replaced by SINAMICS DCM 6RA8085‑6GV62‑0AA0)
Compliance CE, UL, CSA, ATEX (Zone 2)

Electrical Specifications (Armature Circuit – Core)

Parameter Value Unit Remarks
Input Voltage (3‑phase) 575 (±10%) V AC 50/60 Hz, grid‑synchronized
Input Current (Max. Continuous, 575 V) 500 A At rated input voltage, full load
Rated Armature Output Voltage 690 V DC Controllable 0‑690 V DC
Rated Armature Output Current (Iₙ) 600 A 690 V DC, continuous operation
Rated Output Power (Armature) 414 kW Calculated as Vₙ × Iₙ (690 V × 600 A)
Overload Capacity (1 min/10 min) 900 A 150% of Iₙ, 1 minute / 10 minutes duty cycle
Overload Power (1 min/10 min) 621 kW 690 V DC × 900 A
Peak Current (2 sec) 1200 A 200% of Iₙ, 2 seconds
DC Bus Voltage (Nominal) 720–750 V DC Rectified from 575 V AC
Control Voltage 24 (±15%) V DC Auxiliary power supply, current consumption 1.5 A
Insulation Voltage 1400 V AC (1 min) Dielectric strength test value
Short‑Circuit Withstand 300% Iₙ for 0.5 s A Internal semiconductor fuses (IEC 60947‑4‑1 compliant)

Electrical Specifications (Field Circuit – Default)

Parameter Value Unit Remarks
Field Output Voltage (Max.) 375 V DC Controllable 0‑375 V DC
Field Output Current (Max.) 30 A Continuous operation (configurable via field module)
Field Control Mode Current‑controlled (CC) / Voltage‑controlled (VC) (switchable)
Field Insulation Voltage 1000 V AC (1 min) Dielectric strength test value

Hardware Configuration (Options Included)

Component Details
Communication Interface K11 (LBA local bus adapter for I/O expansion); K01 (slot adapter for communication module installation)
Power Semiconductor Thyristor bridge (armature, B6A connection); thyristor bridge (field)
Cooling System Forced air cooling (dual fans, redundant design)
Expansion Slots 2 × optional I/O modules (for analog/digital I/O extension)
Protective Devices Semiconductor fuses (armature: 800 A; field: 40 A), varistors for surge protection

Thermal & Environmental

Parameter Value Unit Derating/Notes
Operating Temperature (No Derating) 0‑40 °C Continuous operation
Operating Temperature (Derating) 40‑55 °C Linear derating at 2%/°C above 40°C
Storage Temperature ‑25‑70 °C No condensation allowed
Relative Humidity 5‑95 % Non‑condensing, no corrosive gases
Altitude (No Derating) ≤1000 m Standard condition
Altitude (Derating) >1000 m 1% derating per 100 m above 1000 m
Vibration Resistance 5‑150 Hz, 0.5 g Compliant with IEC 60068‑2‑6
Shock Resistance 10 g, 11 ms Compliant with IEC 60068‑2‑27
Sound Pressure Level (1 m) ≤78 dB (50/60 Hz) Typical operation noise

Safety & Protection Features

Feature Details
Overvoltage Protection DC bus varistor + active voltage clamping (triggers at ~850 V DC)
Overcurrent Protection Electronic current limiting (up to 1200 A peak)
Overheating Protection Thermal sensor + fan speed control (triggers at 85°C heatsink temperature)
Undervoltage Protection Triggers at 460 V AC input (3‑phase)
Short‑Circuit Protection Internal semiconductor fuses + electronic trip (response time < 1 ms)
Motor Protection Motor overload, stall, and field loss protection
Regenerative Braking Protection Overvoltage clamping during regeneration (4‑quadrant operation)