Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA8093-4GV62-0AA0 SINAMICS DCM DC converter 575 V 3 AC, 1328 A

Part Number: 6RA8093-4GV62-0AA0
Manufacturer Brands: SIEMENS
Place of Originr: Made in Finland
Net Weight: 151,00 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

1. Core Electrical Ratings

Parameter Value Notes
Model 6RA8093-4GV62-0AA0 4GV62 = 4‑quadrant, 690 V AC input class; 0AA0 = standard configuration
3‑phase Input Voltage (Nominal) 690 V AC 50/60 Hz
Input Voltage Range 500 V … 690 V AC -15% / +10% tolerance
Rated Armature Current (Continuous) 1200 A DC 40°C, 100% duty cycle
Peak Armature Current 1800 A DC 1.5 × rated, max 2 seconds
Rated Armature Output Voltage 700 V DC At rated input voltage
Rated Output Power 840 kW Calculated: 700 V × 1200 A
Integrated Field Supply Built‑in, 2‑phase controllable Standard on DCM
Rated Field Voltage 460 V DC Max field output voltage
Rated Field Current Range 1 – 50 A DC Adjustable; max 50 A continuous
Control Supply Voltage 24 V DC / 110–230 V AC Auxiliary power for control logic
Short‑Circuit Withstand Rating (SCCR) 65 kA For power section protection
Typical Power Loss ~42 kW At full rated load (estimated)

2. Control & Performance

Parameter Value
Control Modes Speed control, Torque control, Current control
Speed Regulation Accuracy ±0.01% of rated speed (with encoder)
Current Control Bandwidth Fast digital current loop
Safe Torque Off (STO) Standard, PL d / SIL 2 certified
Motor Feedback Support TTL, HTL, SinCos encoders
Built‑in PID Controller Standard for process control
Regenerative Braking Full 4‑quadrant, energy‑feedback capability
Winder Function Integrated for winding/unwinding applications

3. Thermal & Environmental

Parameter Value Notes
Cooling Method Forced‑air cooling Internal fan
Operating Ambient Temp 0 … +40°C Derate 1% per °C above 40°C
Storage Temperature -40 … +55°C Non‑condensing
Relative Humidity 5 … 95% RH Non‑condensing
Altitude ≤ 1000 m Derate 1% per 100 m above 1000 m
Pollution Degree 2 Per IEC 60664‑1

4. Mechanical Data

Parameter Value
Protection Class IP00 (open chassis) For cabinet installation
Frame Size D8 Standard DCM frame
Dimensions (H × W × D) 800 mm × 400 mm × 400 mm Approx (31.5 × 15.7 × 15.7 in)
Net Weight 120 kg Approx (264.5 lbs)
Mounting Vertical wall/cabinet mount Vertical orientation only
Isolation Test Voltage 3.0 kV AC Power section to ground

5. Standard Interfaces

Interface Specification
Analog Inputs 4 × 0–10 V / 0–20 mA (isolated)
Analog Outputs 3 × 0–10 V / 0–20 mA (isolated)
Digital Inputs 8 × 24 V DC (PNP/NPN configurable)
Digital Outputs 5 × 24 V DC / 2 A (solid‑state)
Encoder Interface TTL / HTL / SinCos
Fieldbus Options (Pluggable) PROFIBUS DP, CANopen, Modbus TCP, PROFINET, EtherCAT
Motor Temperature Input 1 × PTC

Leave a Replay