Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

8440-2050 For Woodward Easygen 3200-5/P1 Generator Controller Caterpillar

Woodward 8440-2050
Alternate PN: Woodward 8440-2050
Manufacturer Brands: Woodward
Place of Originr: Made in Germany

Inquire this item

Woodward 8440-2050

8440-2050 For Woodward Easygen 3200-5/P1 Generator Controller Caterpillar

Woodward 8440-2050 easYgen-3200-5/P1 Generator Controller Specification
Basic Model Identification
Parameter Specification Note
Part Number 8440-2050 Woodward official part number
Full Model Name easYgen-3200-5/P1 P1 base model, split busbar logic
Firmware Version Rev F Mainstream stock version
Origin German Design, Poland Assembly
Application Scenarios Caterpillar Generator Sets, Split Bus AMF, Multi-unit Parallel, Grid-tied Peak Shaving, CHP
Power Supply Electrical Parameters
Parameter Specification Note
Control Power Supply 12/24 VDC Wide operating range: 8~40 VDC
Maximum Power Consumption 19 W
Digital Input Rated 12/24 VDC Active signal
Relay Contact Rating 250 VAC / 5A Resistive load
Insulation Withstand Voltage 300 VAC (phase-ground) Surge withstand: 4kV
Voltage/Current Measurement Circuit (PT/CT)
Parameter Specification Note
Measurement Frequency 40~85 Hz 50/60Hz adaptive
Rated Phase Voltage (IEC) 120/480V△ Maximum measurement: 600VAC
Current Transformer Rating 5A AC Dual independent channels for generator and mains
Primary Current Setting Range 1~32000 A
Measurement Accuracy 0.5 class Metering grade
Input Impedance 2MΩ per phase High resistance, low loss
Built-in I/O Hardware (P1 Standard)
Parameter Specification Note
Programmable Digital Inputs (DI) 14 channels Built-in
Programmable Relay Outputs (DO) 12 channels For unit start/stop, switching, alarm
CANopen Extended I/O Support Not supported P1 version does not support external discrete I/O expansion (P2 supports 16DI/16DO)
Built-in Analog Inputs (AI) 3 channels 0~500Ω resistance signal, 4~20mA current transmitter
Built-in Analog Outputs (AO) 2 channels ±10V / ±20mA / PWM three-mode output, direct drive of Woodward governor and AVR
Speed Measurement Input Magnetic Pickup Overspeed/underspeed monitoring
Parallel & Busbar Core Capabilities
Parameter Specification Note
Busbar Architecture Dual Split Bus Built-in automatic bus coupler switching logic
Maximum Units per Controller 8 units System total networking up to 32 units (Peer-to-Peer)
Synchronization Performance Closed-loop automatic synchronization Grid closing impact suppression, closing time <2s
Load Distribution Accuracy ±3% kW/kVAR dynamic sharing, constant power factor control supported
Operating Modes Island, Grid-tied, AMF Automatic Transfer, Peak Shaving, Load Priority Unloading, CHP
Protection Functions
Parameter Specification Note
Engine Protection Overspeed/Underspeed, Low Oil Pressure, High Water Temperature, Emergency Stop, Start Failure, Shutdown Fault, Sensor Wire Break
Generator Electrical Protection Overvoltage/Undervoltage, Overfrequency/Underfrequency, Reverse Power, Overcurrent, Three-phase Unbalance, Ground Fault, Excitation Fault, Loss of Synchronization
Busbar/Mains Protection Overcurrent, Bus Coupler Switch Interlock, Grid Loss, Reverse Power Protection Compliant with IEEE C37.102 standard
Human Machine Interface (HMI)
Parameter Specification Note
Display 5.7-inch Color LCD Soft key operation
Languages 14 languages Including Simplified Chinese, English, German, French, Spanish, Russian, Japanese
Functions Real-time Single-line Diagram, Operation Trend Curve, SOE Event Sequence Recording, Multi-level Password Permission
Configuration Method Local Screen Setting + PC Woodward ToolKit Software Debugging
Communication Interfaces
Parameter Specification Note
CAN 2.0B 2 channels For electronic governor, AVR, unit internal CAN instruments
RS485 1 channel Modbus RTU, for upper monitoring, DCS, SCADA docking
RS232 1 channel Local PC ToolKit debugging port
Native Ethernet Not supported External gateway required for network access
Mechanical Dimensions & Protection
Parameter Specification Note
Overall Dimensions 250mm (W) × 227mm (H) × 50mm (D)
Panel Cutout Standard 3000 Series Panel Cutout Size
Protection Rating IP66 (Screw Mount), IP54 (Snap-in Mount), IP20 (Rear Terminals)
Housing Material Flame-retardant Plastic Embedded panel mounting
Net Weight Approx. 1.85 kg
Environmental Operating Parameters
Parameter Specification Note
Operating Temperature -20℃ ~ +70℃
Storage Temperature -30℃ ~ +80℃
Relative Humidity 0~95% Non-condensing
Certifications UL, CE, RoHS Industrial control certifications
Key Limitations of P1 Version
Parameter Specification Note
3-channel Independent PID Closed-loop Control Not supported
CANopen External Extended Analog I/O Not supported
Multi-channel Cylinder Temperature Monitoring Expansion Not supported
Suitable Scenario Standard single unit / split busbar generator set basic control for Caterpillar

Leave a Replay