6SE7031-2HG60 | 6SE70312HG60 SIMOVERT MD Converter unit 3AC 660-690V, 110KW

SIEMENS
Alternate PN: 6SE7031-2HG60
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 165,000 Kg

Inquire this item

SIEMENS

6SE7031-2HG60 | 6SE70312HG60

SIMOVERT MD Converter unit 3AC 660-690V, 110KW

SIMOVERT MASTERDRIVES VECTOR CONTROL CONVERTER CHASSIS UNIT, IP00 3 660-690V AC, 50/60HZ, 118 A NOM. POWER RATINGS: 110KW DOCUMENTATION ON CD

 

Product Series: SIMOVERT MASTERDRIVES VC (Vector Control) Frequency Converter

1. Basic Electrical Specifications

Parameter Value
Model Number 6SE7031-2HG60
Device Type Chassis-mounted vector control frequency converter
Rated Power 110 kW (147.5 HP)
Rated Output Current 118 A (nominal)
Input Voltage 3-phase AC, 660–690 V
Input Frequency 50/60 Hz (auto-adapting)
Output Voltage 0–input voltage (3-phase AC)
Output Frequency Range 0–300 Hz (standard)
Control Modes V/f control, Sensorless vector control, Closed-loop vector control (with encoder)
DC Link Voltage 740–890 V DC (nominal)
Cooling Method Forced air cooling (standard)
Protection Degree IP00 (cabinet installation)

2. Performance & Overload Data

Parameter Value
Overload Capacity 150% of In for 60 sec (every 300 sec)
Torque Accuracy Closed-loop vector: ±2% of rated torque
Speed Stability Closed-loop (encoder): ±0.01% of max. speed
Switching Frequency 2–16 kHz (adjustable)
Dynamic Response Fast current/torque control (ms-level)

3. Environmental Ratings

Parameter Value
Operating Temperature 0–40 °C (vertical, no derating); 0–60 °C (horizontal, derated above 40°C)
Storage Temperature -25–+70 °C
Relative Humidity 5–95% RH (non-condensing)
Max. Operating Altitude ≤1000 m (no derating); derated above 1000 m
Vibration Resistance IEC 60068-2-6: 1 g (10–58 Hz)
Shock Resistance IEC 60068-2-27: 15 g (11 ms)

4. Interfaces & Connections

Interface Details
Analog Inputs 2 channels (0–10 V, ±10 V, 0–20 mA, 4–20 mA)
Analog Outputs 2 channels (0–10 V, 0–20 mA)
Digital Inputs 6–8 optically isolated inputs (24 V DC)
Digital Outputs 3–4 relay outputs (30 V DC / 250 V AC, 5 A)
Encoder Interface Supports TTL/HTL encoders (sin/cos optional)
Communication Ports – Serial: RS232/RS485

– Optional: PROFIBUS-DP, DeviceNet, Modbus, CANopen

5. Protection & Diagnostics

Function Description
Overcurrent Protection IGBT short-circuit, output short-circuit protection
Overvoltage Protection DC link overvoltage, input surge protection
Overtemperature Heat sink / IGBT overtemperature warning & trip
Phase Loss Input phase failure, output phase imbalance detection
Motor Protection PTC thermistor input, overload monitoring
Fault History Stores last 8–10 faults with time stamps

6. Physical & Mechanical Data

Parameter Value
Weight Approx. 75 kg
Mounting Vertical cabinet mounting
Cable Entry Top/bottom power terminals; front control terminals