6SE7031-5TF60 | 6SE70315TF60
SIMOVERT MD Inverter unit DC 510-650V, 75KW
SIMOVERT MASTERDRIVES VECTOR CONTROL INVERTER CHASSIS UNIT, IP00 510-650V DC, 146 A NOM. POWER RATINGS: 75KW DOCUMENTATION ON CD
Siemens 6SE7031-5TF60 Complete Technical Parameters (English)
Basic & Electrical Specifications
表格
| Item | Specification |
|---|---|
| Order Number | 6SE7031-5TF60 |
| Product Series | SIMOVERT MASTERDRIVES MC Vector Control |
| Type | Chassis-mounted inverter, IP00 |
| Input Voltage | 3AC 380–460 V |
| Input Frequency | 45–66 Hz |
| Rated Output Power | 75 kW |
| Rated Output Current | 146 A |
| Overload Current | 219 A (150% for 60s / 5min) |
| Peak Current | 292 A (200% for 3s) |
| Output Voltage | 0–input voltage (380–460 V AC) |
| Output Frequency | 0–300 Hz |
| DC Link Voltage | 510 V DC nominal |
| Switching Frequency | 2–16 kHz adjustable |
| Control Modes | V/f control, vector control (encoder/encoderless), torque control |
| Speed Accuracy (encoder) | ±0.01% of rated speed |
| Speed Accuracy (sensorless) | ±0.5% of rated speed |
| Torque Response | <5 ms |
| Cooling | Forced air cooling |
| Protection Functions | Overcurrent, overvoltage, undervoltage, overtemperature, short circuit, earth fault, safe stop |
Environmental & Mechanical Data
表格
| Item | Specification |
|---|---|
| Ambient Temperature | 0–40 °C (derating above 40°C) |
| Storage Temperature | -25–+70 °C |
| Humidity | 5–95% RH, non-condensing |
| Max. Operating Altitude | 1000 m (derating above 1000 m) |
| Protection Class | IP00 |
| Weight | Approx. 65 kg |
Communication & Functions
表格
| Item | Specification |
|---|---|
| Standard Interface | USS |
| Optional Fieldbus | PROFIBUS DP, CAN, SIMOLINK |
| Built-in Functions | S-ramp, PID, DC braking, flycatch restart, torque limit, slip compensation, positioning, synchronism |