Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

8F3B25‑BDDBAEAFABSAAASAA2+AA Proline Promass F 300 Coriolis mass flowmeter

Endress+Hauser 8F3B25‑BDDBAEAFABSAAASAA2+AA Proline Promass F 300 Coriolis Mass Flowmeter, DN25 (1"), high‑accuracy multi‑variable mass flow sensor for liquid and gas process measurement
Alternate PN: 8F3B25‑BDDBAEAFABSAAASAA2+AA
Manufacturer Brands: E+H
Place of Originr: Made in Germany

Inquire this item

Endress+Hauser 8F3B25‑BDDBAEAFABSAAASAA2+AA Proline Promass F 300 Coriolis Mass Flowmeter, DN25 (1"), high‑accuracy multi‑variable mass flow sensor for liquid and gas process measurement

8F3B25‑BDDBAEAFABSAAASAA2+AA is Proline Promass F 300 Coriolis mass flowmeter from Endress+Hauser. It implements Coriolis measuring principle, simultaneously measuring mass flow, volume flow, density and medium temperature without inlet straight pipe requirements. It supports Heartbeat Technology for continuous self‑diagnosis and in‑situ device verification, reducing recalibration cycles. The dual‑compartment transmitter housing supports multiple configurable I/O interfaces and touch‑operated backlit display with WLAN access. Wetted parts adopt high‑grade corrosion‑resistant stainless steel material, adapting to harsh chemical, oil‑gas and food‑grade process conditions. It delivers stable high‑precision measurement independent of medium viscosity, density and flow profile. Suitable for new project installation, field spare‑part replacement and process retrofit jobs in process industries。

 

Item Specification
Full Order Code 8F3B25‑2K558/0

8F3B25‑BDDBAEAFABSAAASAA2+AA

Nominal Diameter DN25, 1″
Certification ATEX+IECEx; Z0/1, Z21, Ex d, IIC/IIIC
Power Supply DC 24V
Input / Output 1 4‑20mA HART
Input / Output 2 Pulse / Frequency / Switch output
Input / Output 3 None
Display & Operation 4‑line backlight, touch control
Housing Material Aluminum, coated
Electrical Connection M20 thread
Wetted Measuring Tube Material Stainless steel, unpolished
Process Connection CL150 RF, 1.4404/316/316L, Flange ASME B16.5
Flow Calibration Accuracy 0.10% mass
Device Model Version 2
Operation Language English
Selected Medium Liquid
Current Output 1 Mass flow
Current Range 4…20 mA NAMUR
4 mA Value 0 kg/h
20 mA Value 3600.00000 kg/h
Fail‑safe Current Output Maximum value
Damping Output 1 1.00000 s
Operating Mode Pulse
Assigned Pulse Output Mass flow
Pulse Value(per pulse) 1.00000 kg
Pulse Width 100.00000 ms
Fail‑safe Pulse Output No pulse
Display Format 1 value, maximum size

 