Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6SL3220-3YD56-0CB0 SIEMENS SINAMICS G120XA Rated power 315kW 3AC 380V -20% to 440V +10%

Alternate PN: 6SL3 220-3YD56-0CB0,6SL32203YD560CB0
Manufacturer Brands: SIEMENS
Place of Originr: Made in China
Net Weight: 132.000 Kg

Inquire this item

EurAutomation.com is a professional supplier of industrial automation products, providing integrated solutions, such as PLC, HMI, CNC, DRIVES, CNC, INVERTER, VFDs, frequency converter cabinet, DC speed control cabinet, widely used in industrial automation, process automation, humanoid robots, intelligent factories, unmanned workshops, no matter what your procurement needs are, you only need to send an email. We will serve you as soon as possible.

6SL3220-3YD56-0CB0

SINAMICS G120XA Rated power 315kW 3AC 380V -20% to 440V +10% Integrated class A C3 filter 110% 60s per 600s with integrated IOP-2 Integrated Fieldbus: MODBUS RTU, BACnet MS/TP, USS 6DI, 4DQ, 2AI, 2AQ, 1Mot_t Protection: IP20 Frame Size: FSH 1487.5x548x410 (HxWxD)
Category
Item
Parameter
Inputs / Outputs
Analog outputs – Number
2 (Non-isolated output)
Inputs / Outputs
Analog / digital inputs – Number
2 (Differential input)
Inputs / Outputs
Analog / digital inputs – Resolution
12 bit
Inputs / Outputs
Analog / digital inputs – Switching threshold: 0 → 1
4 V
Inputs / Outputs
Analog / digital inputs – Switching threshold: 1 → 0
1.6 V
General Technical Specifications
Efficiency η
0.98
General Technical Specifications
EMC category (with accessories)
Category C3
Closed-loop Control Techniques
Encoderless torque control
Yes
Inputs / Outputs
Fail-safe digital inputs – Number
0
General Technical Specifications
Filter class (integrated)
RFI suppression filter for Category C3
General Technical Specifications
Power loss³)
6.890 kW
General Technical Specifications
Power factor cos φ 1
0.99
General Technical Specifications
Power factor λ
0.75 … 0.93
Rated Data
Max. output current
770.00 A
Rated Data
Max. output current (overload)
Max. output current for 60 s in a 600 s cycle time
Rated Data
Low Overload (LO)
110% base load current IL for 60 s in a 600 s cycle time
Rated Data
Line frequency
47 … 63 Hz
Rated Data
Line voltage
380 … 440 V +10 % -15 %
Communication
Communication interfaces
USS, Modbus RTU, BACnet MS/TP
Rated Data
Pulse frequency
2 kHz
Inputs / Outputs
PTC / KTY interface – Motor temperature sensor input
1, sensors that can be connected: PTC, KTY, PT1000 and Thermo-Click, accuracy ±5 ℃
Rated Data
Rated current (LO)
617.00 A
Rated Data
Rated current (LO)
568.00 A
Rated Data
Rated current 400V (IN)
582.62 A
Rated Data
Rated current 380V (IN)
605.00 A
Rated Data
Rated power IEC 400V (LO)
315.00 kW
Rated Data
Rated voltage
400 V
General Technical Specifications
Safety function “Safe Torque Off”
Without SIRIUS device (e.g. via S7-1500F)
General Technical Specifications
Sound pressure level (1m)
72.9 dB
Inputs / Outputs
Standard digital inputs – Number
6
Inputs / Outputs
Standard digital inputs – Max. inrush current
15 mA
Inputs / Outputs
Standard digital inputs – Switching level: 0 → 1
11 V
Inputs / Outputs
Standard digital inputs – Switching level: 1 → 0
5 V
Closed-loop Control Techniques
Sensorless vector control
Yes
Inputs / Outputs
Digital outputs – Number as relay changeover contact
4
Inputs / Outputs
Digital outputs – Number as transistor
0
Inputs / Outputs
Digital outputs – Output (resistive load)
DC 30 V, 1.0 A
Rated Data
Output phases
3 AC
Rated Data
Output frequency for vector control
0 … 100 Hz
Rated Data
Output frequency for V/f control
0 … 100 Hz
Rated Data
Input phases
3 AC
Closed-loop Control Techniques
V/f with flux current control (FCC)
Yes
Closed-loop Control Techniques
V/f ECO linear / square-law
Yes
Closed-loop Control Techniques
V/f linear / square-law / parameterizable
Yes
Closed-loop Control Techniques
Vector control, with sensor
No
Closed-loop Control Techniques
Torque control, with encoder
No

Leave a Replay