Woodward 9907-1183

Woodward 9907-1183 is a 24V 505E digital turbine governor with a 32-bit processor for steam turbine speed, load and extraction pressure control. It features 6 analog I/O channels, dual Modbus RS485 ports and ±0.25% speed accuracy. With wide temperature tolerance, IP54 front panel and Class I Div 2 certification, it suits power plant turbogenerators and petrochemical turboexpanders.
Alternate PN: Woodward 9907-1183
Manufacturer Brands: B&R
Place of Originr: Made in Germany

Inquire this item

Woodward 9907-1183 is a 24V 505E digital turbine governor with a 32-bit processor for steam turbine speed, load and extraction pressure control. It features 6 analog I/O channels, dual Modbus RS485 ports and ±0.25% speed accuracy. With wide temperature tolerance, IP54 front panel and Class I Div 2 certification, it suits power plant turbogenerators and petrochemical turboexpanders.

Woodward 9907-1183

Woodward 9907-1183 (505E Low-Voltage Digital Turbine Governor) Technical Specifications

Item Specification
Part Number 9907-1183
Official Model Name 505E Enhanced Digital Turbine Governor (24V Low-Voltage Version)
Manufacturer Woodward, USA
Core Processor 32-bit high-speed microcontroller
Primary Function Closed-loop speed, load, extraction/admission pressure control for steam turbines
Nominal Power Supply 24 V DC
Operating DC Voltage Range 18 V DC ~ 32 V DC
Typical Power Consumption ≤ 25 W
Main HMI Interface Integrated membrane keypad + multi-line LCD display
Analog Input Channels 6 isolated analog inputs (4–20 mA / 0–10 V selectable)
Analog Output Channels 6 isolated analog outputs (4–20 mA drive for servo actuators)
Serial Communication Ports 2 independent Modbus RTU/ASCII ports (RS485)
Configuration Software Woodward Control Assistant PC software
Speed Regulation Steady-State Accuracy ±0.25% rated speed
Control Loop Execution Time < 10 ms cycle time
Built-in Control Algorithms PID speed control, extraction/admission PID, load sharing, ratio limiter, over-speed protection logic
Safety Functions Zero-speed detection, turbine over-speed trip, parameter password protection
Front Panel Protection Rating IP54 (dust & splash resistant)
Rear Terminal Protection Class IP20
Continuous Operating Temperature -40 °C ~ +70 °C
Recommended Stable Working Range -25 °C ~ +65 °C
Storage & Transit Temperature -40 °C ~ +85 °C
Ambient Humidity 5%–95% RH, non-condensing
Overall Dimension (W × H × D) 356 mm × 279 mm × 102 mm
Net Unit Weight Approx. 1.8 kg
Mounting Type Panel flush mounting for control cabinet
Conformal Coating Sulfur-resistant conformal coated circuit board
Compatibility Standalone operation or integration with plant DCS systems
Typical Applications Utility steam turbogenerators, industrial extraction steam turbines, turboexpanders, mechanical drive compressors in power & petrochemical plants
Certifications CE, industrial EMC compliance, Class I Division 2 hazardous location rated