Such: Siemens 6SL3120... ...

Sales03@aotewell.com
Mob/WhatsAPP: +86-133-6088-4385

6RA8031-6GV62-0AA0 SINAMICS DCM DC converter 575V 3AC, 104A

SINAMICS DCM DC Converter FOR FOUR-QUADRANT DRIVES CONNECTION (B6) A (B6) C INPUT: 3-PHASE AC 575V, 104A CONTROLLABLE FIELD RECTIFIER D600/125 MREQ-GEG6V62 OUTPUT: DC 600V, 125A
Part Number: 6RA8031-6GV62-0AA0
Alternate PN: 6RA80316GV620AA0
Manufacturer Brands: SIEMENS
Place of Originr: Made in Germany
Net Weight: 15,00 Kg
Product Size: 380.00 x 520.00 x 390.00 mm

Inquire this item

SINAMICS DCM DC Converter FOR FOUR-QUADRANT DRIVES CONNECTION (B6) A (B6) C INPUT: 3-PHASE AC 575V, 104A CONTROLLABLE FIELD RECTIFIER D600/125 MREQ-GEG6V62 OUTPUT: DC 600V, 125A

Core Electrical Specifications

Parameter Value Notes
Product Type SINAMICS DCM 4-Quadrant DC Converter Circuit: (B6)A (B6)C
Rated Input Voltage 3-phase AC 575 V Frequency: 45–65 Hz
Rated Input Current 104 A At rated load
Permissible Input Voltage Range 3-phase AC 488 V – 633 V 85%–110% of rated
Rated Output Voltage DC 600 V Armature circuit
Rated Output Current 125 A Armature continuous (40°C, 100% duty)
Peak Output Current 200 A 160% of rated, max 2s
Field Rectifier Type Controllable (D600/125) Integrated
Rated Field Voltage DC 375 V Max field voltage
Rated Field Current 10 A Continuous field supply
Power Loss (Typical) 1.8 kW At rated load
Power Rating (Typical) 75 kW DC output (600V × 125A)
Electronics Supply 24 V DC 0.8 A typical

Power & Thermal

Parameter Value Notes
Cooling Method Forced air (internal fan) IP00 protection
Ambient Temperature (Operation) 0°C – 40°C Derate 2.5%/°C above 40°C
Ambient Temperature (Storage) -40°C – 70°C Non-condensing
Relative Humidity 5% – 95% Non-condensing
Altitude ≤ 1000 m Derate 1%/100m above 1000 m

Mechanical & Protection

Parameter Value Notes
Protection Class IP00 (open chassis)
Dimensions (W×H×D) 268 mm × 385 mm × 252 mm Without terminal covers
Net Weight 15 kg Unpacked
Mounting Free-standing / rack-mount Vertical orientation
Isolation Power section isolated from ground 2.5 kV AC test voltage
Short-Circuit Protection Electronic current limiting Adjustable trip levels
Overvoltage Protection Varistor + active clamping Input & output sides
Overtemperature Protection Thermal sensor + shutdown At heatsink & IGBTs

Communication & Control

Interface/Feature Details
Standard Communication PROFIBUS DP RS-485 port, 12 Mbps max
Optional Communication PROFINET RT/IRT Via CBE30 module
Analog Inputs 4 × 0–10 V / 0–20 mA Isolated, 12-bit resolution
Analog Outputs 2 × 0–10 V / 0–20 mA Isolated, 12-bit resolution
Digital Inputs 6 × 24 V DC PNP/NPN selectable
Digital Outputs 4 × 24 V DC, 2 A Relay-free (solid-state)
Control Modes V/f, speed, torque, current Field-oriented control (FOC)
Control Accuracy Speed: ±0.01% (encoder); Torque: ±1% With encoder feedback
Enclosure Coating Conformal coating (3C2) For harsh environments

Leave a Replay